Purpose: To validate the fundus image grading results by a trained grader (Non-ophthalmologist) and an ophthalmologist grader for detecting diabetic retinopathy (DR) and diabetic macular oedema (DMO) against fundus examination by a retina specialist (gold standard).
Methods: A prospective diagnostic accuracy study was conducted using 2002 non-mydriatic colour fundus images from 1001 patients aged ≥40 years. Using the Aravind Diabetic Retinopathy Evaluation Software (ADRES) images were graded by both a trained non-ophthalmologist grader (grader-1) and an ophthalmologist (grader-2). Sensitivity, specificity, positive predictive value and negative predictive value were calculated for grader-1 and grader-2 against the grading results by an independent retina specialist who performed dilated fundus examination for every study participant.
Results: Out of 1001 patients included, 42% were women and the mean ± (SD) age was 55.8 (8.39) years. For moderate or worse DR, the sensitivity and specificity for grading by grader-1 with respect to the gold standard was 66.9% and 91.0% respectively and the same for the ophthalmologist was 83.6% and 80.3% respectively. For referable DMO, grader-1 and grader-2 had a sensitivity of 74.6% and 85.6% respectively and a specificity of 83.7% and 79.8% respectively.
Conclusions: Our results demonstrate good level of accuracy for the fundus image grading performed by a trained non-ophthalmologist which was comparable with the grading by an ophthalmologist. Engaging trained non-ophthalmologists potentially can enhance the efficiency of DR diagnosis using fundus images. Further study with multiple non-ophthalmologist graders is needed to verify the results and strategies to improve agreement for DMO diagnosis are needed.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10220051 | PMC |
http://dx.doi.org/10.1038/s41433-022-02190-4 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!