Objectives: To evaluate the prognostic value of fully automatic lung quantification based on spectral computed tomography (CT) and laboratory parameters for combined outcome prediction in COVID-19 pneumonia.

Methods: CT images of 53 hospitalized COVID-19 patients including virtual monochromatic reconstructions at 40-140keV were analyzed using a fully automated software system. Quantitative CT (QCT) parameters including mean and percentiles of lung density, fibrosis index (FIBI-700, defined as the percentage of segmented lung voxels ≥-700 HU), quantification of ground-glass opacities and well-aerated lung areas were analyzed. QCT parameters were correlated to laboratory and patient outcome parameters (hospitalization, days on intensive care unit, invasive and non-invasive ventilation).

Results: Best correlations were found for laboratory parameters LDH (r = 0.54), CRP (r = 0.49), Procalcitonin (r = 0.37) and partial pressure of oxygen (r = 0.35) with the QCT parameter 75th percentile of lung density. LDH, Procalcitonin, 75th percentile of lung density and FIBI-700 were the strongest independent predictors of patients' outcome in terms of days of invasive ventilation. The combination of LDH and Procalcitonin with either 75th percentile of lung density or FIBI-700 achieved a r2 of 0.84 and 1.0 as well as an area under the receiver operating characteristic curve (AUC) of 0.99 and 1.0 for the prediction of the need of invasive ventilation.

Conclusions: QCT parameters in combination with laboratory parameters could deliver a feasible prognostic tool for the prediction of invasive ventilation in patients with COVID-19 pneumonia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9337660PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0271787PLOS

Publication Analysis

Top Keywords

laboratory parameters
16
lung density
16
qct parameters
12
75th percentile
12
percentile lung
12
covid-19 pneumonia
8
patient outcome
8
lung
8
parameters
8
ldh procalcitonin
8

Similar Publications

Ledged Beam Walking Test Automatic Tracker: Artificial intelligence-based functional evaluation in a stroke model.

Comput Biol Med

January 2025

Neurological Sciences and Cerebrovascular Research Laboratory, Department of Neurology and Stroke Centre, Neurology and Cerebrovascular Disease Group, Neuroscience Area La Paz Institute for Health Research (idiPAZ), (La Paz University Hospital- Universidad Autónoma de Madrid), Spain. Electronic address:

The quantitative evaluation of motor function in experimental stroke models is essential for the preclinical assessment of new therapeutic strategies that can be transferred to clinical research; however, conventional assessment tests are hampered by the evaluator's subjectivity. We present an artificial intelligence-based system for the automatic, accurate, and objective analysis of target parameters evaluated by the ledged beam walking test, which offers higher sensitivity than the current methodology based on manual and visual counting. This system employs a residual deep network model, trained with DeepLabCut (DLC) to extract target paretic hindlimb coordinates, which are categorized to provide a ratio measurement of the animal's neurological deficit.

View Article and Find Full Text PDF

Electrochemical impedance spectroscopy has great potential for laboratory blood tests. The overall aim of this study is to develop a microfluidic sensor for determining the physical properties and hematological parameters of blood based on its dielectric spectra. Impedance was measured in flowing blood to prevent aggregation and sedimentation at frequencies between 40 Hz and 110 MHz.

View Article and Find Full Text PDF

A platform combining automatic segmentation and automatic measurement of the maxillary sinus and adjacent structures.

Clin Oral Investig

January 2025

State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, 610041, China.

Objectives: To develop a platform including a deep convolutional neural network (DCNN) for automatic segmentation of the maxillary sinus (MS) and adjacent structures, and automatic algorithms for measuring 3-dimensional (3D) clinical parameters.

Materials And Methods: 175 CBCTs containing 242 MS were used as the training, validating and testing datasets at the ratio of 7:1:2. The datasets contained healthy MS and MS with mild (2-4 mm), moderate (4-10 mm) and severe (10- mm) mucosal thickening.

View Article and Find Full Text PDF

Clinical and imaging characteristics of 135 cases of infectious sacroiliitis: a retrospective cohort study in China.

Clin Rheumatol

January 2025

Department of Rheumatology and Immunology, The First Medical Center, People Liberation Army General Hospital, Beijing, 100853, China.

To study the clinical, imaging, and computed tomography (CT)-guided biopsy pathology of patients with infectious sacroiliitis (ISI). We retrospectively analysed 135 patients diagnosed with ISI between 2008 and 2020, comprehensively evaluating clinical characteristics, laboratory test outcomes, pathological examination results, and magnetic resonance images (MRI). Among the 135 patients with ISI, 90 (66.

View Article and Find Full Text PDF

Context: Natural fluorapatite (FAP) has been investigated as an adsorbent for the removal of dyes such as methylene blue (MB) and crystal violet (CV) from aqueous solutions. Effective dye removal is crucial for water treatment, particularly for industrial wastewater containing toxic dyes. FAP, a naturally abundant material, was characterized using XRD, FTIR, and SEM analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!