Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Electrocardiogram (ECG) signal conditioning is a vital step in the ECG signal processing chain that ensures effective noise removal and accurate feature extraction.
Objective: This study evaluates the performance of the FDA 510 (k) cleared HeartKey Signal Conditioning and QRS peak detection algorithms on a range of annotated public and proprietary ECG databases (HeartKey is a UK Registered Trademark of B-Secur Ltd).
Methods: Seven hundred fifty-one raw ECG files from a broad range of use cases were individually passed through the HeartKey signal processing engine. The algorithms include several advanced filtering steps to enable significant noise removal and accurate identification of the QRS complex. QRS detection statistics were generated against the annotated ECG files.
Results: HeartKey displayed robust performance across 14 ECG databases (seven public, seven proprietary), covering a range of healthy and unhealthy patient data, wet and dry electrode types, various lead configurations, hardware sources, and stationary/ambulatory recordings from clinical and non-clinical settings. Over the NSR, MIT-BIH, AHA, and MIT-AF public databases, average QRS Se and PPV values of 98.90% and 99.08% were achieved. Adaptable performance (Se 93.26%, PPV 90.53%) was similarly observed on the challenging NST database. Crucially, HeartKey's performance effectively translated to the dry electrode space, with an average QRS Se of 99.22% and PPV of 99.00% observed over eight dry electrode databases representing various use cases, including two challenging motion-based collection protocols.
Conclusion: HeartKey demonstrated robust signal conditioning and QRS detection performance across the broad range of tested ECG signals. It should be emphasized that in no way have the algorithms been altered or trained to optimize performance on a given database, meaning that HeartKey is potentially a universal solution capable of maintaining a high level of performance across a broad range of clinical and everyday use cases.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9484027 | PMC |
http://dx.doi.org/10.1111/anec.12993 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!