Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The authors have previously described the Unified Visual Function Scale (UVFS). Here, we assessed intra- and interobserver reliability of the scale, and investigated correlations with patient quality of life (QoL). Eight healthcare practitioners independently applied the UVFS in 20 representative cases from our parasellar meningioma series. Scoring was compared with consensus grades assigned by lead authors. Inter- and intraobserver agreement was measured using intraclass correlation coefficient (ICC), Fleiss's κ, and Cohen's κ, respectively. Patient QoL was assessed Visual Function Questionnaire 25 (VFQ-25) or Activities of Daily Vision Scale (ADVS), and correlated with UVFS grades for each eye. The interobserver ICC was 0.734 (95% confidence interval [CI]: 0.652-0.811), with Fleiss's κ of 0.758, 0.691, and 0.899 for grades A, B, and C, respectively. The intraobserver ICC was 0.758 (95% CI: 0.638-0.872), and Fleiss's κ was 0.604, 0.268, and 0.910 for grades A, B, and C respectively. The Cohen's κ for agreement between UVFS category grades and consensus grades was 0.816 (95 CI: 0.698-0.934). Survey response rate was 51% (27/53). The UVFS demonstrated strong correlation with VFQ-25 subdivisions general vision ( = 0.7712), near activities ( = 0.7262), peripheral vision ( = 0.6722), and driving ( = 0.6608), and also demonstrated strong correlation with the overall ADVS score ( = 0.5902). This study shows that the UVFS is valid within a small subset of observers, and accurately reflects patient QoL. It is robust and practical, which make it suitable for broad implementation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9324316 | PMC |
http://dx.doi.org/10.1055/a-1680-1429 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!