A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An acute gastroenteritis outbreak associated with a contaminated water supply system, Turkey, 2018. | LitMetric

An acute gastroenteritis outbreak associated with a contaminated water supply system, Turkey, 2018.

J Water Health

General Directorate of Public Health, Ministry of Health of Turkey, Adnan Saygun St, Çankaya, Ankara, Turkey E-mail:

Published: July 2022

Disruption of routine monitorization and chlorination of the water supply system during a week-long holiday led to a multi-organism gastroenteritis outbreak in a district with limited laboratory support. More than a 10-fold increase in patients with gastroenteritis was reported. Enteropathogenic Escherichia coli, Enteroaggregative E. coli, and norovirus were detected in human specimen samples. The main water tank and pipes were rusted; 13 out of the 19 water samples tested positive for total Coliform (1-920 colony-forming units (CFU)/100 ml) and E. coli (1-720 CFU/100 ml). Chlorine levels were below 0.2 ppm in seven of the nine samples. Information of 1,815 cases was obtained from the hospital records with a crude attack rate of 2.9%. Cases widespread in the district increased throughout the holiday, epidemic curve revealed a point-source outbreak. The case-control study revealed that consumption of drinking tap water and using it to clean vegetables/fruits were significantly associated with the illness. While drinking only bottled water had a protective effect against the illness. The culture technique showed that the water supply samples were positive for pathogenic bacteria. Upon decision in a multi-stakeholder meeting, the water tank was cleaned, and the Municipality initiated the renovation of the water supply system.

Download full-text PDF

Source
http://dx.doi.org/10.2166/wh.2022.037DOI Listing

Publication Analysis

Top Keywords

water supply
16
supply system
12
water
9
gastroenteritis outbreak
8
water tank
8
acute gastroenteritis
4
outbreak associated
4
associated contaminated
4
contaminated water
4
supply
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!