Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate arterial spin labeling (ASL) and diffusion-weighted imaging (DWI) in discrimination of benign from malignant paranasal sinus (PNS) tumors.
Material And Methods: A prospective study was done upon 42 cases of PNS masses that underwent magnetic resonance ASL and DWI of the head. Tumor blood flow (TBF) and apparent diffusion coefficient (ADC) of the masses were calculated by two observers. The pathological diagnosis was malignant (n = 28) and benign (n = 14) cases.
Results: For both observers, the malignant PNS masses had significantly higher TBF (P < 0.001, 0.001) and lower ADC (P < 0.001, 0.001) than in benign masses. The ROC curve analysis of TBF, The threshed TBF was (121.45, 122.68 mL/100 g/min) used for differentiation between benign and malignant PNS masses, revealed sensitivity (92.9%, 89.3%), specificity (85.7%, 85.7%), accuracy (90.5%, 88.1%) and the AUC was 0.87 and 0.86 by both observers. the ROC curve analysis of ADC, The threshold ADC (1.215, 1.205 X10mm2/s) was used for differentiation between benign and malignant PNS masses, revealed sensitivity (96.4%, 89.3%), specificity (78.6%, 78.6%), accuracy of (90.5%, 85.7%) and the AUC was 0.93 and 0.92 by both observers. Combined analysis of TBF and ADC used for differentiation between benign and malignant PNS masses had revealed sensitivity (96.4%, 89.3%), specificity (92.9%, 85.7%) accuracy of (95.2%, 88.1%) and AUC. (0.995, 0.985) for both observers.
Conclusion: Combined using of TBF and ADC have a role in differentiation malignant from benign PNS masses.