Purpose: The application of 3D exoscopic technology is spreading worldwide, in several surgical scenarios. In this study, we present the first-time use of the exoscopic system (VITOM® and Versacrane™) in a cadaver simulation of transoral Snore Surgery.
Methods: All participants (n = 14) were asked to perform 2 exercises that simulate tasks required in Snore Surgery, they were then administered a questionnaire assessing their evaluation of the applied exoscopic technology. Participants were divided into groups according to age and experience.
Results: Mean zooming and focusing time was higher in young surgeons than in seniors, and similar results were obtained for mean procedural times. The responses to the questionnaire showed that in the vast majority (86%), the exoscopic technology was well rated.
Conclusion: The exoscope can be considered a useful tool, thanks to its magnifying power and high-definition images, as well as for its indirect ability to enhance staff involvement in the procedure and for educational purposes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11325-022-02684-1 | DOI Listing |
BMC Surg
January 2025
Department of Neurosurgery, Neurosurgery Clinic, Birgunj, Nepal.
Background: Microvascular decompression (MVD) is the gold-standard surgical treatment for cranial nerve compression disorders, including trigeminal neuralgia (TN), hemifacial spasm (HFS), and glossopharyngeal neuralgia (GPN). This review synthesizes historical milestones, recent advances, and evolving techniques in MVD, with a primary focus on these conditions.
Methods: A comprehensive literature review was conducted using databases such as PubMed, SpringerLink, Google Scholar, BioMed Central, Scopus, and ScienceDirect.
J Robot Surg
January 2025
BG Trauma Center Ludwigshafen, Department for Plastic, Hand and Reconstructive Surgery, Department of Plastic Surgery for the Heidelberg University, Ludwig-Guttmann-Straße 13, 67071, Ludwigshafen, Germany.
Robot-assisted surgery represents a significant innovation in reconstructive microsurgery, providing enhanced precision and reduced surgeon fatigue. This study examines the integration of robotic assistance in a series of 85 consecutive robot-assisted microsurgical (RAMS) operations. It aims to evaluate changes in the integration of RAMS during the implementation phase in a single institution.
View Article and Find Full Text PDFNeurosurg Focus
December 2024
1Department of Biomedical Sciences, Humanitas University; and.
Objective: Microvascular decompression (MVD) in trigeminal neuralgia (TN) is currently managed using an operating microscope (OM). Recent experiences with endoscopy-assisted, fully endoscopic, and exoscopic surgery have been described, aiming to improve ergonomics and image quality. The aim of this study was to report the first series of patients operated on with the aid of a robotic binocular exoscope using a head-mounted display (RoboticScope).
View Article and Find Full Text PDFSensors (Basel)
November 2024
Department of Otorhinolaryngology, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.
Augmented reality technologies provide transformative solutions in various surgical fields. Our research focuses on the use of an advanced augmented reality system that projects 3D holographic images directly into surgical footage, potentially improving the surgeon's orientation to the surgical field and lowering the cognitive load. We created a novel system that combines exoscopic surgical footage from the "ORBEYE" and displays both the surgical field and 3D holograms on a single screen.
View Article and Find Full Text PDFJ Int Adv Otol
September 2024
Evelina Children's Health, London, UK.