Copper slag (CPS) is a large amount of waste material produced during the manufacture of copper. The disposal of this waste material becomes a problem for environmental concerns. Therefore, it is necessary to explore feasible alternate disposal options. They may also be utilized in concrete manufacturing to cut down on the usage of cement and natural aggregates. A lot of researchers focus on utilizing CPS in concrete, either as a cement replacement or as a filler material. This article aims to summarize the literature already carried out on CPS in conventional concrete to identify the influence of CPS on the fresh, hardened and durability performance of cement concrete. Results indicate that CPS improved the strength and durability performance of concrete but simultaneously decreased the slump value of concrete. Furthermore, an increase in the durability performance of concrete was also observed with CPS. However, the higher dose results declined in mechanical and durability aspects owing to a scarcity of flowability. Therefore, it is suggested to use the optimum dose of CPS. However, a different researcher recommends a different optimum dose ranging from 50 to 60% by weight of fine aggregate depending on the source of CPS. The review also recommends future researcher guidelines on CPS in concrete.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9332793 | PMC |
http://dx.doi.org/10.3390/ma15155196 | DOI Listing |
J Agric Food Chem
January 2025
College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China.
Challenges emerge in the quest for highly efficient and biocompatible coatings to tackle microbial contamination. Here, we propose a bioinspired paradigm combining (-)-epigallocatechin gallate (EGCG) and l-arginine surfactants (LAM) as all-green building blocks for advanced coatings with superior performance. Molecular dynamics simulations reveal the natural assembly process of the EGCG/LAM supramolecular nanoparticles (ELA NPs).
View Article and Find Full Text PDFBioresour Technol
January 2025
College of Urban Construction, Wuhan University of Science and Technology, Wuhan 430065, China.
Ammonia-oxidizing bacteria (AOB) sourced from an aerobic granular sludge (AGS) process were rapidly enriched by progressively increasing ammonia nitrogen (NH-N) loads, achieving a Nitrosomonas abundance of 20.7 % and a nitrite accumulation rate exceeding 80 %. Mycelial pellets formed by Cladosporium, isolated from the same AGS system, provided a porous surface structure for the immobilization of the enriched AOB, creating mycelial pellet/AOB composites.
View Article and Find Full Text PDFRofo
January 2025
Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
To evaluate the feasibility of liver tract embolization after transhepatic biliary drainage using a biodegradable polymer plug (IMPEDE-FX, Shape Memorial Medical, Santa Clara, CA, USA).In a retrospective observational study, 15 plug embolizations were performed in 13 patients at risk for tract-related adverse events (AEs). Risk factors included coagulopathy, cirrhosis, central bile duct puncture, previous drain-related bleeding, malignant obstruction, large tract diameter, or multilevel strictures.
View Article and Find Full Text PDFEuropace
January 2025
Division of Cardiology, McGill University Medical Center, Montreal, Quebec, Canada.
Background: Loss of bipolar electrograms immediately after pulsed field ablation (PFA) makes lesion durability assessment challenging.
Objective: The aim of this trial (NCT06700226) was to evaluate a novel ablation system that can optically predict lesion durability by detecting structural changes in the tissue during ablation.
Methods: Patients with paroxysmal atrial fibrillation underwent pulmonary vein isolation (PVI) using PFA (AblaView®, MedLumics).
Background: Initial clinical studies of pulsed field ablation (PFA) to treat atrial fibrillation (AF) indicated a >90% durability rate of pulmonary vein isolation (PVI). However, these studies were largely conducted in single centers and involved a limited number of operators. The electrophysiological findings and outcomes in patients undergoing repeat ablation after an initial PF ablation for AF are incompletely understood.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!