Objective: To evaluate pulmonary vein (PV)-to-pulmonary artery (PA) ratios obtained in healthy dogs by means of various CT protocols, accounting for the effects of the respiratory phase and contrast agent used.

Animals: 10 healthy Beagles.

Procedures: Before and after contrast medium (600 mg iodine/kg) was injected IV, thoracic CT was performed with a positive-pressure breath-hold (inspiratory phase) and at the end of expiration (expiratory phase). After CT scanning, echocardiography was performed, and an optimized right parasternal long-axis view was obtained for measurement of PV and PA diameters. The PV and PA diameters were measured subsequently for each CT protocol.

Results: Mean ± SD PV:PA values obtained from pre- and postcontrast inspiratory CT were 1.058 ± 0.072 and 1.020 ± 0.053, respectively, which were comparable to the echocardiographic value (P > .05). Mean PV:PA values obtained with pre- and postcontrast expiratory CT were 1.259 ± 0.094 and 1.239 ± 0.066, respectively, which were significantly (P = .005) greater than inspiratory CT measurements. There was a significant (r > 0.5, P < .05) linear relationship between PV:PA values obtained with pre- and postcontrast inspiratory CT and echocardiography.

Clinical Relevance: PV:PA could be measured with thoracic CT in a manner similar to that for echocardiography. However, PV:PA values measured with expiratory CT were different from previously reported values. Therefore, the respiratory phase should be considered when evaluating pulmonary vascular size through CT, and measurements with the inspiratory CT protocol would be more accurate.

Download full-text PDF

Source
http://dx.doi.org/10.2460/ajvr.22.02.0026DOI Listing

Publication Analysis

Top Keywords

pvpa values
16
respiratory phase
12
values pre-
12
pre- postcontrast
12
postcontrast inspiratory
8
inspiratory
5
pvpa
5
values
5
phase affect
4
affect pulmonary
4

Similar Publications

Lamellar membranes obtained by stacking 2D layers possess ample transport pathways due to their intricate network of interlayer gaps. This makes them suitable for molecular separation applications. However, controlling the surface chemistry of the nanochannels within the membrane to tune the desired transport properties of water and ions is challenging.

View Article and Find Full Text PDF

Development of a novel human stratum corneum mimetic phospholipid -vesicle-based permeation assay models for permeation studies.

Drug Dev Ind Pharm

May 2024

Jiangsu Provincial Engineering Research Center of TCM External Medication Development and Application, Nanjing University of Chinese Medicine, Nanjing, PR China.

Objectives: To develop and evaluate a novel human stratum corneum (SC) mimetic phospholipid vesicle-based permeation assay (PVPA) model for permeation studies.

Significance: Due to the increasing restrictions on the use of human and animal skins, artificial skin models have attracted substantial interest in pharmaceuticals and cosmetic industries. In this study, a modified PVPA model containing both SC lipids and proteins was developed.

View Article and Find Full Text PDF

Echocardiographic Assessment of the Pulmonary Vein to Pulmonary Artery Ratio in Canine Heartworm Disease.

Animals (Basel)

February 2023

Internal Medicine, Veterinary Medicine and Therapeutic Research Group, Faculty of Veterinary Medicine, Research Institute of Biomedical and Health Sciences (IUIBS), Universidad de Las Palmas de Gran Canaria (ULPGC), 35016 Las Palmas de Gran Canaria, Spain.

Unlabelled: produces proliferative pulmonary endarteritis and pulmonary thromboembolism in infected dogs. The pulmonary vascular lesions lead to irreversible and persistent structural damage and, as a consequence, sustained precapillary pulmonary hypertension (PH). The purpose of this study was to assess the diagnostic value of the pulmonary vein to pulmonary artery ratio (PV:PA ratio) to determine moderate or severe PH (>50 mmHg) in dogs with heartworm disease.

View Article and Find Full Text PDF

Measurement of fetal atrioventricular intervals in pregnant women with anti-SSA/Ro antibodies.

J Med Ultrason (2001)

July 2022

Fujita Clinic, Shimanouchi Building 2F, 2-11-20 Shimanouchi, Chuo-ku, Osaka-shi, Osaka, 542-0082, Japan.

Purpose: The objective of our study was to compare and consider reference values of fetal atrioventricular (AV) intervals as measured by four different pulsed Doppler wave techniques (left ventricular inflow/outflow [LV in/out], pulmonary vein/pulmonary artery [PV/PA], innominate vein/ascending aorta [InnV/AA], and supra vena cava/ascending aorta [SVC/AA]) in pregnant women with anti-SSA/Ro antibodies.

Methods: Between March 2014 and September 2020, 52 pregnant women with anti-SSA antibodies were enrolled. No bradyarrhythmia was observed in the group.

View Article and Find Full Text PDF

Fractional Flow Reserve in End-Stage Liver Disease.

Am J Cardiol

March 2022

Division of Cardiology, Department of Medicine, University of California, Los Angeles, Los Angeles, California. Electronic address:

Article Synopsis
  • * Data was collected from 42 ESLD patients who underwent right-sided cardiac catheterization, measuring parameters such as resting coronary pressure and using a modified FFR (FFR-P) formula, revealing one stenosis that was reclassified as significant.
  • * Results indicated that a lower FFR (≤0.80) was linked to significantly higher all-cause mortality rates at one year (73% vs 17%), suggesting FFR is an important predictor of outcomes even
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!