Evaluation of IOL power calculation with the Kane formula for pediatric cataract surgery.

Graefes Arch Clin Exp Ophthalmol

Department of Ophthalmology, Rabin Medical Center, 39 Jabotinski St, Petach Tikva, Israel.

Published: September 2022

Purpose: To assess the accuracy of the Kane formula for intraocular lens (IOL) power calculation in the pediatric population.

Methods: The charts of pediatric patients who underwent cataract surgery with in-the-bag IOL implantation with one of two IOL models (SA60AT or MA60AC) between 2012 and 2018 in The Hospital for Sick Children, Toronto, Ontario, CanFada, were retrospectively reviewed. The accuracy of IOL power calculation with the Kane formula was evaluated in comparison with the Barrett Universal II (BUII), Haigis, Hoffer Q, Holladay 1, and Sanders-Retzlaff-Kraff Theoretical (SRK/T) formulas.

Results: Sixty-two eyes of 62 patients aged 6.2 (IQR 3.2-9.2) years were included. The SD values of the prediction error obtained by Kane (1.38) were comparable with those by BUII (1.34), Hoffer Q (1.37), SRK/T (1.40), Holaday 1 (1.41), and Haigis (1.50), all p > 0.05. A significant difference was observed between the Hoffer Q and Haigis formulas (p = 0.039). No differences in the median and mean absolute errors were found between the Kane formula (0.54 D and 0.91 ± 1.04 D) and BUII (0.50 D and 0.88 ± 1.00 D), Hoffer Q (0.48 D and 0.88 ± 1.05 D), SRK/T (0.72 D and 0.97 ± 1.00 D), Holladay 1 (0.63 D and 0.94 ± 1.05 D), and Haigis (0.57 D and 0.98 ± 1.13 D), p = 0.099.

Conclusion: This is the first study to investigate the Kane formula in pediatric cataract surgery. Our results place the Kane among the noteworthy IOL power calculation formulas in this age group, offering an additional means for improving IOL calculation in pediatric cataract surgery. The heteroscedastic statistical method was first implemented to evaluate formulas' predictability in children.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00417-022-05779-3DOI Listing

Publication Analysis

Top Keywords

kane formula
20
iol power
16
power calculation
16
cataract surgery
16
pediatric cataract
12
calculation kane
8
formula pediatric
8
calculation pediatric
8
kane
7
iol
6

Similar Publications

To compare the accuracy of seven artificial intelligence (AI)-based intraocular lens (IOL) power calculation formulas in medium-long Caucasian eyes regarding the root-mean-square absolute error (RMSAE), the median absolute error (MedAE) and the percentage of eyes with a prediction error (PE) within ±0.5 D. Data on Caucasian patients who underwent uneventful phacoemulsification between May 2018 and September 2023 in MW-Med Eye Center, Krakow, Poland and Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Kyiv, Ukraine were reviewed.

View Article and Find Full Text PDF

Intraocular lens power calculation in cataract patients with keratoconus: Bayesian network meta-analysis.

Int Ophthalmol

January 2025

Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, No.1, Dong Jiao Min Xiang, Dong Cheng District, Beijing, 100730, China.

Purpose: To compare the accuracy of intraocular lens (IOL) power calculation formulas in cataract patients with keratoconus (KC).

Methods: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analysis statementand and was registered on PROSPERO (CRD42024568997). Pubmed, Web of Science, Cochrane Library, and EMBASE were searched for retrospective and prospective clinical studies published until October 2024.

View Article and Find Full Text PDF

Purpose: To compare changes in angle morphology, anterior chamber depth (ACD) and refractive prediction error (PE) after phacoemulsification between pseudoexfoliative (PEX) and non-PEX eyes.

Methods: Prospective case-control study of eyes submitted to cataract surgery. Biometric data and angle parameters - Anterior Chamber Angle (ACA), Angle Opening Distance (AOD), Scleral Spur Angles (SSA) and Trabecular Iris Space Area (TISA) - were measured preoperatively and 1-month postoperatively through swept-source anterior segment optical coherence tomography.

View Article and Find Full Text PDF

Background: This study aims to comprehensively evaluate the predictive accuracy of six widely used toric intraocular lens (IOL) calculators in eyes undergoing cataract surgery with toric IOL implantation.

Methods: This retrospective study reviewed 53 eyes of 53 patients that underwent cataract extraction with toric IOL implantation using Zeiss 709 M. Six toric IOL calculators were evaluated: Barrett toric calculator (with predicted PCA, measured PCA, and TK), Kane formula (predicted PCA), and EVO 2.

View Article and Find Full Text PDF

Intraocular lens calculation formula selection for short eyes: based on axial length and anterior chamber depth.

BMC Ophthalmol

January 2025

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong, China.

Purpose: To evaluate the predictive accuracy of 11 intraocular lens (IOL) calculation formulas in eyes with an axial length (AL) less than 22.00 mm.

Methods: New-generation formulas (Barrett Universal II [BUII], Emmetropia Verifying Optical [EVO] 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?