BACKGROUND: Reading capsule endoscopy (CE) is time-consuming. The Express View (EV) (IntroMedic, Seoul, Korea) software was designed to shorten CE video reading. Our primary aim was to evaluate the diagnostic accuracy of EV in detecting significant small-bowel (SB) lesions. We also compared the reading times with EV mode and standard reading (SR). METHODS: 126 patients with suspected SB bleeding and/or suspected neoplasia were prospectively enrolled and underwent SB CE (MiroCam®1200, IntroMedic, Seoul, Korea). CE evaluation was performed in standard and EV mode. In case of discrepancies between SR and EV readings, a consensus was reached after reviewing the video segments and the findings were re-classified. RESULTS: The completion rate of SB CE in our cohort was 86.5% and no retention occurred. The per-patient analysis of sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of EV compared to SR were 86%, 86%, 90%, 81%, and 86%, respectively, before consensus. After consensus, they increased to 97%, 100%, 100%, 96%, and 98%, respectively. The median reading time with SR and EV was 71 min (range 26−340) and 13 min (range 3−85), respectively (p < 0.001). CONCLUSIONS: The new-generation EV shows high diagnostic accuracy and significantly reduces CE reading times.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9332221PMC
http://dx.doi.org/10.3390/diagnostics12081783DOI Listing

Publication Analysis

Top Keywords

reading times
12
diagnostic accuracy
12
express view
8
capsule endoscopy
8
intromedic seoul
8
seoul korea
8
min range
8
reading
7
generation express
4
view artificial
4

Similar Publications

Importance: Mental health issues among young people are increasingly concerning. Conventional psychological interventions face challenges, including limited staffing, time commitment, and low completion rates.

Objective: To evaluate the effect of a low-intensity online intervention on young people in Hong Kong experiencing moderate or greater mental distress.

View Article and Find Full Text PDF

Determination of the optimal method for measuring malondialdehyde in human saliva.

MethodsX

June 2025

Centre des Sciences du Goût et de l'Alimentation, CNRS, INRAE, Institut Agro, Université de Bourgogne, F-21000 Dijon, France.

While few methodological studies have been published on the salivary measurement of malondialdehyde (MDA), none have precisely detailed the analytical method. This work presents the development of an analytical method for MDA measurement in microvolumes of saliva samples from healthy individuals, using thiobarbituric acid derivatization and fluorescence reading of the formed compound. This method was progressively designed to meet specific constraints such as the limited sample volume available, cost-effectiveness of each assay, time required for analysis and costs.

View Article and Find Full Text PDF

The lack of thematic continuity in dreams with scene and plot discontinuities.

Sleep Adv

December 2024

EPISTEME Research and Strategy, Brooklyn, NY, USA.

A central tenet of Freudian dream theory holds that there is thematic coherence within all dreams, even those containing scene and plot discontinuities. While other models support varying degrees of dream coherence, none address the question of how, or even whether, coherence can be identified in dreams with such discontinuities. Here, we objectively test the ability of judges to evaluate the coherence of individual dream narratives.

View Article and Find Full Text PDF

Purpose: To validate the performance of the Notal OCT Analyzer (NOA) in processing self-administered OCT images from an OCT system designed for home use (home OCT [HOCT]) as part of a pivotal study aimed at achieving de novo United States Food and Drug Admininstration marketing authorization.

Design: A prospective quantitative cross-sectional artificial intelligence study.

Participants: The study enrolled adults aged ≥55 years diagnosed with neovascular age-related macular degeneration (nAMD) in ≥1 eligible eye with a best-corrected visual acuity of 20/320 or better.

View Article and Find Full Text PDF

Introduction: This is a double clinical trial conducted to study the patient satisfaction and comfort during and after surgical removal of impacted mandibular 3rd molar using Piezo electric tips.

Material And Methods: Two groups of 25 each [14 (56 %) males and 11 (44 %) females] and [18 (72 % males and 07 (28 %) females] represented the Rotary and Piezo groups respectively with bilateral impactions. one side of the patient is operated by piezo and the other side by rotary instrument after a gap of 2-3 week between the procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!