In this work, we examined novel polymer composites for use in radiation protection applications. These prepared polymers are non-toxic compared with lead and show potential to be used as protective gear in different medical applications where low-energy photons are utilized. We prepared silicon rubber (SR) with different concentrations of micro- and nano-sized MgO. We used a HPGe detector to measure radiation attenuation factors at different photon energies, ranging from 59.6 to 1333 keV. We reported the effect of particle size on the attenuation parameters and found that the linear attenuation factors for SR with nano-MgO were higher than for SR with micro-MgO. The mean free path (MFP) for pure SR and SR with micro- and nano-sized MgO were determined, and we found that silicon rubber with MgO (both micro- and nano-sized) has a lower MFP than pure SR. The linear attenuation coefficient results show the importance of using SR with high MgO content for low-energy radiation protection applications. Moreover, the half-value layer (HVL) results demonstrate that we need a certain thickness of SR with nano-MgO to effectively reduce the intensity of the low-energy photons.