Intraoperative Circulatory Support in Lung Transplantation: Current Trend and Its Evidence.

Life (Basel)

Department of Anaesthesiology and Intensive Care Medicine, Hannover Medical School, 30625 Hannover, Germany.

Published: July 2022

Lung transplantation has a high risk of haemodynamic complications in a highly vulnerable patient population. The effects on the cardiovascular system of the various underlying end-stage lung diseases also contribute to this risk. Following a literature review and based on our own experience, this review article summarises the current trends and their evidence for intraoperative circulatory support in lung transplantation. Identifiable and partly modifiable risk factors are mentioned and corresponding strategies for treatment are discussed. The approach of first identifying risk factors and then developing an adjusted strategy is presented as the ERSAS (early risk stratification and strategy) concept. Typical haemodynamic complications discussed here include right ventricular failure, diastolic dysfunction caused by left ventricular deconditioning, and reperfusion injury to the transplanted lung. Pre- and intra-operatively detectable risk factors for the occurrence of haemodynamic complications are rare, and the therapeutic strategies applied differ considerably between centres. However, all the mentioned risk factors and treatment strategies can be integrated into clinical treatment algorithms and can influence patient outcome in terms of both mortality and morbidity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9322250PMC
http://dx.doi.org/10.3390/life12071005DOI Listing

Publication Analysis

Top Keywords

risk factors
16
lung transplantation
12
haemodynamic complications
12
intraoperative circulatory
8
circulatory support
8
support lung
8
risk
7
lung
5
transplantation current
4
current trend
4

Similar Publications

Background: Near-infrared spectroscopy (NIRS) enables a non-invasive measurement of tissue oxygen saturation (StO) in regions illuminated by near-infrared lights. Vascular occlusion test (VOT) serves as a model to artificially induce forearm ischemia-reperfusion. The combination of StO monitoring and VOT allows for dynamic evaluation of the balance between oxygen delivery and consumption in tissue, as well as the functional reserve of microcirculation.

View Article and Find Full Text PDF

Implant failure of the Compress prosthesis: a case report.

J Med Case Rep

January 2025

Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya University Hospital, 65 Tsurumai, Showa, Nagoya, Aichi, 466-8550, Japan.

Background: The Compress is designed to achieve bone formation and stability by applying pressure at the bone-implant interface, minimizing the likelihood of aseptic loosening, which is a complication of stem implants. Herein, we report two cases of implant failure using the Compress.

Case Presentation: Case 1 describes a 36 year-old Japanese man who underwent extraarticular tumor resection, Compress arthroplasty, and reconstruction with a gastrocnemius flap after preoperative chemotherapy for a secondary malignant giant cell tumor in the right distal femur.

View Article and Find Full Text PDF

Background: Adequate knowledge and awareness regarding diseases are essential for appropriate, high-quality healthcare. Female Genital Schistosomiasis (FGS) is a non-sexually transmitted gynaecological disease that is caused by the presence of Schistosoma haematobium eggs in the female genital tract and the resulting immune response that causes tissue damage. It is estimated to affect 56 million women, mostly in sub-Saharan Africa (SSA), where healthcare workers (HCWs) have limited awareness and knowledge of FGS.

View Article and Find Full Text PDF

Background: Despite advancements in Human Immunodeficiency Virus (HIV) treatment and care, undernutrition remains a significant concern, accelerating disease progression and risk of Acquired Immune Deficiency Syndrome (AIDS)-related deaths. The nutritional status of second-line antiretroviral treatment (SLART) users in Ethiopia has not been thoroughly investigated. So, this study aimed to assess the nutritional status of HIV/AIDS patients who were on SLART and its associated factors in Northern Ethiopia.

View Article and Find Full Text PDF

Application of low-intensity anticoagulation after On-X mechanical aortic valve replacement.

J Cardiothorac Surg

January 2025

Cardiac Surgery Center, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Affiliated Hospital of University of Electronic Science and Technology, Chengdu, Sichuan Province, 610072, China.

Objective: To explore the safety and efficacy of low-intensity anticoagulation in patients after On-X mechanical aortic valve replacement.

Methods: A total of 104 patients undergoing aortic valve replacement in Cardiac Surgery Department of Sichuan Provincial People's Hospital from December 2018 to December 2021 were randomly divided into low-intensity anticoagulant (INR:1.5-2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!