Purpose: This study was carried out to investigate the accuracy of referring different locations of the patellar tendon attachment site and the geometrical center of the osteotomy surface for tibial rotational alignment and observe the influences of gender differences on the results.

Methods: Computed tomography scans of 135 osteoarthritis patients (82 females and 53 males) with varus deformity was obtained to reconstruct three-dimensional (3D) models preoperatively. The medial boundary, medial one-sixth, and medial one-third of the patellar tendon attachment site were marked on the tibia. These points were projected on the tibial osteotomy plane and connected to the geometrical center (GC) of the osteotomy plane or the middle of the posterior cruciate ligament (PCL) to construct six tibial rotational axes (Akagi line, MBPT, MSPT1, MSPT2, MTPT1 and MTPT2). The mismatch angle between the vertical line of the SEA projected on the proximal tibial osteotomy surface and six different reference axes was measured. In additional, the effect of gender differences on rotational alignment for tibial component were assessed.

Results: Relative to the SEA, rotational mismatch angles were - 1.8° ± 5.1° (Akagi line), - 2.5° ± 5.3° (MBPT), 2.8° ± 5.3° (MSPT1), 4.5° ± 5.4° (MSPT2), 7.3° ± 5.4° (MTPT1), and 11.6° ± 5.8° (MTPT2) for different tibial rotational axes in all patients. All measurements differed significantly between the male and female. The tibial rotational axes with the least mean absolute deviation for the female or male were Akagi line or MSPT, respectively. There was no significant difference in whether the GC of the osteotomy surface or the midpoint of PCL termination was chosen as the posterior anatomical landmark when the medial boundary or medial one-sixth point of the patellar tendon attachment site was selected as the anterior anatomical landmark.

Conclusion: When referring patellar tendon attachment site as anterior anatomical landmarks for tibial rotational alignment, the influence of gender difference on the accuracy needs to be taken into account. The geometric center of the tibial osteotomy plane can be used as a substitute for the middle of the PCL termination when reference the medial boundary or medial one-sixth of the patellar tendon attachment site.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9327362PMC
http://dx.doi.org/10.1186/s13018-022-03248-5DOI Listing

Publication Analysis

Top Keywords

patellar tendon
24
tendon attachment
24
attachment site
24
tibial rotational
24
rotational alignment
16
gender differences
12
osteotomy surface
12
medial boundary
12
boundary medial
12
medial one-sixth
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!