A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intensive 90-day textile wearable Holter monitoring: an alternative to detect paroxysmal atrial fibrillation in selected patients with cryptogenic stroke. | LitMetric

We aimed to demonstrate the feasibility of 90-day cardiac monitoring with an external Holter device and to find a target population able to benefit from such a technique. Cryptogenic stroke patients were continuously monitored for 90 days with a textile wearable Holter (TWH). Compliance and quality of the monitoring were assessed by the number of hours of ECG stored per month. Mean predictors of pAF, including age, gender, stroke severity, and atrial size (LAVI), were evaluated. One-year follow-up assessed pAF detection outside per protocol monitoring. Out of 224 patients included in 5 stroke centers, 163 patients (72.76%) fulfilled the criteria for the protocol. Median monitoring time was similar among the three months. Per protocol pAF detection reached 35.37% at 90 days. The age (OR 1.095; 95% CI 1.03-1.14) and the LAVI (OR 1.055; 95% CI 1.01-1.09) independently predicted pAF. The cut-off point of 70 years (AUC 0.68) (95% CI 0.60-0.76) predicted pAF with a sensitivity of 75.8% and specificity of 50.5%. The LAVI cut-off point of 28.5 (AUC 0.67) (95% CI 0.56-0.77) had a sensitivity of 63.6% and a specificity of 61.8% to detect pAF. The combination of both markers enhanced the validity of pAF detection sensitivity to 89.6%, with a specificity of 27.59%. These patients had increased risk of pAF during the 90-day monitoring HR 3.23 (χ 7.15) and beyond 90 days (χ 5.37). Intensive 90-days TWH monitoring detected a high percentage of pAF. However, a significant number of patients did not complete the monitoring. Patients older than 70 years and with enlarged left atria benefitted more from the protocol.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00380-022-02141-9DOI Listing

Publication Analysis

Top Keywords

paf detection
12
paf
9
textile wearable
8
wearable holter
8
monitoring
8
cryptogenic stroke
8
predicted paf
8
cut-off point
8
patients
7
intensive 90-day
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!