Lower refractive prediction accuracy of total keratometry using intraocular lens formulas loaded onto a swept-source optical biometer.

Graefes Arch Clin Exp Ophthalmol

Department of Ophthalmology, Osaka Minato Central Hospital, Japan Community Health Care Organization (JCHO), 1-7-1 Isoji, Minato-ku, Osaka, 552-0003, Japan.

Published: January 2023

Purpose: To compare refractive outcomes calculated using intraocular lens (IOL) power calculation formulas loaded onto the IOLMaster 700 with the employment of anterior keratometry (K) and total keratometry (TK).

Methods: A total of 225 eyes of 225 patients underwent uneventful cataract surgery and implantation of a single model of nontoric monofocal IOL by a single surgeon. All eyes underwent preoperative ocular biometric measurements with the IOLMaster 700. Refractive outcomes, including the mean numerical prediction error (MNE); standard deviation (SD); adjusted mean absolute prediction error (MAE); adjusted median absolute prediction error (MedAE); percentages of eyes with adjusted prediction error (PE) within ± 0.25, ± 0.50, ± 0.75, and ± 1.00 diopter; and IOL Formula Performance Index (FPI), were compared between the K-based formula and the TK-based formula of Barrett Universal II (BUII), Haigis, SRK/T, Holladay 2, and Hoffer Q. Axial length (short, medium, and long) subgroup analyses and anterior and posterior keratometry (flat, medium, and steep) subgroup analyses were conducted.

Results: The K-based formula performed better than the TK-based formula in the accuracy of refractive prediction of each IOL calculation formula: BUII-K (FPI 0.690), BUII-TK (0.677), Haigis-K (0.617), Haigis-TK (0.584), SRK/T-K (0.608), SRK/T-TK (0.595), Holladay 2-K (0.419), Holladay 2-TK (0.406), Hoffer Q-K (0.364), and Hoffer Q-TK (0.356). The subgroup analyses of refractive prediction outcomes showed that TK influenced the refractive outcomes in eyes with relatively normal ranges of axial length and anterior keratometry.

Conclusions: Using TK instead of K leads to lower refractive prediction accuracy of the IOL power calculation formulas loaded on the IOLMaster 700.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00417-022-05777-5DOI Listing

Publication Analysis

Top Keywords

refractive prediction
16
prediction error
16
formulas loaded
12
refractive outcomes
12
iolmaster 700
12
subgroup analyses
12
lower refractive
8
prediction
8
prediction accuracy
8
total keratometry
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!