Electrotactile stimulation has been commonly used in human-machine interfaces to provide feedback to the user, thereby closing the control loop and improving performance. The encoding approach, which defines the mapping of the feedback information into stimulation profiles, is a critical component of an electrotactile interface. Ideally, the encoding will provide a high-fidelity representation of the feedback variable while being easy to perceive and interpret by the subject. In the present study, we performed a closed-loop experiment wherein discrete and continuous coding schemes are combined to exploit the benefits of both techniques. Subjects performed a muscle activation-matching task relying solely on electrotactile feedback representing the generated myoelectric signal (EMG). In particular, we investigated the performance of two different coding schemes (spatial and spatial combined with frequency) at two feedback resolutions (low: 3 and high: 5 intervals). In both schemes, the stimulation electrodes were placed circumferentially around the upper arm. The magnitude of the normalized EMG was divided into intervals, and each electrode was associated with one interval. When the generated EMG entered one of the intervals, the associated electrode started stimulating. In the combined encoding, the additional frequency modulation of the active electrode also indicated the momentary magnitude of the signal within the interval. The results showed that combined coding decreased the undershooting rate, variability and absolute deviation when the resolution was low but not when the resolution was high, where it actually worsened the performance. This demonstrates that combined coding can improve the effectiveness of EMG feedback, but that this effect is limited by the intrinsic variability of myoelectric control. Our findings, therefore, provide important insights as well as elucidate limitations of the information encoding methods when using electrotactile stimulation to convey a feedback signal characterized by high variability (EMG biofeedback).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9458587PMC
http://dx.doi.org/10.1007/s00221-022-06409-4DOI Listing

Publication Analysis

Top Keywords

feedback
8
electrotactile feedback
8
electrotactile stimulation
8
coding schemes
8
combined coding
8
combined
6
encoding
5
electrotactile
5
emg
5
combined spatial
4

Similar Publications

Injured epithelial organs must rapidly replace damaged cells to restore barrier integrity and physiological function. In response, injury-born stem cell progeny differentiate faster compared to healthy-born counterparts, yet the mechanisms that pace differentia-tion are unclear. Using the adult Drosophila intestine, we find that injury speeds cell differentiation by altering the lateral inhibition circuit that transduces a fate-determin-ing Notch signal.

View Article and Find Full Text PDF

This review explores recent technological advances in intraoperative imaging during retinal disease surgeries, focusing on their applicability in clinical practice and impact on surgical outcomes. A literature search identified studies discussing new imaging technologies, their advantages over conventional methods, relevant case studies, and literature reviews. Exclusion criteria included studies unrelated to retinal diseases, imaging technologies not suitable for intraoperative use, outdated articles, and nonscientific reports.

View Article and Find Full Text PDF

Intraoperative optical coherence tomography (iOCT) has been applied and studied in a variety of vitreoretinal surgeries for its feasibility, safety, and outcomes for years. Common scenarios include membrane peeling procedures, retinal detachments, choroidal-retinal biopsies, Argus implants, and subretinal injections. iOCT offers the surgeon a better understanding of the retinal microarchitectural changes and timely intraoperative feedback, directing a future view of precision surgery.

View Article and Find Full Text PDF

Purpose: To evaluate the long-term impacts of the feedback intervention on controlling inappropriate use of antimicrobial prescriptions in primary care institutions in China, as a continuation of the previous feedback intervention trial.

Methods: After the intervention ended, we conducted a 12-month follow-up study. The prescription data were collected from the baseline until the end of the follow-up period.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!