A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Efficacy of Non-contact BallistocardiographySystem to Determine Heart Rate Variability. | LitMetric

Efficacy of Non-contact BallistocardiographySystem to Determine Heart Rate Variability.

Ann Neurosci

Turtle Shell Technologies Pvt. Ltd, Bengaluru, Karnataka, India.

Published: January 2022

Background: Functions of the autonomic nervous system have cardinal importance in day-to-day life. Heart rate variability (HRV) has been shown to estimate the functioning of the autonomic nervous system. Imbalance in the functioning of the autonomic nervous system is seen to be associated with chronic conditions such as chronic kidney disease, cardiovascular diseases, diabetes mellitus, and so on.

Purpose: To evaluate the efficacy of a non-contact ballistocardiography (BCG) system to calculate HRV parameters by comparing them to the parameters derived from a standard commercial software that uses an electrocardiogram (ECG).

Methods: Current study captured an ECG signal using a three-channel ECG Holter machine, whereas the BCG signal was captured using a BCG sensor sheet consisting of vibroacoustic sensors placed under the mattress of the participants of the study.

Results: The study was conducted on 24 subjects for a total of 54 overnight recordings. The proposed method covered 97.92% epochs of the standard deviation of NN intervals (SDNN) and 99.27% epochs of root mean square of successive differences (RMSSD) within 20 ms and 30 ms tolerance, respectively, whereas 98.84% of two-min intervals for low-frequency (LF) to high-frequency (HF) ratio was covered within a tolerance of 1. Kendall's coefficient of concordance was also calculated, giving a P < .001 for all the three parameters and coefficients 0.66, 0.55, and 0.44 for SDNN, RMSSD, and LF/HF, respectively.

Conclusion: The results show that HRV parameters captured using unobtrusive and non-invasive BCG sensors are comparable to HRV calculated using ECG.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9305910PMC
http://dx.doi.org/10.1177/09727531211063426DOI Listing

Publication Analysis

Top Keywords

autonomic nervous
12
nervous system
12
efficacy non-contact
8
heart rate
8
rate variability
8
functioning autonomic
8
hrv parameters
8
non-contact ballistocardiographysystem
4
ballistocardiographysystem determine
4
determine heart
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!