Objective: The study aimed to analyse the detection rates of the triple-lumen double-balloon catheter technique and conventional esophagography in diagnosing H-type tracheoesophageal fistula (H-TEF) in neonates.

Methods: The data of 8 neonates diagnosed with H-TEF by surgery in the researchers' hospital between January 2015 and January 2022 were collected. We compared the detection (true positive) rates of H-TEF by the triple-lumen double-balloon catheter technique, conventional esophagography, and multidetector row spiral CT.

Results: Before surgery, conventional esophagography was applied in all 8 cases, of which the H-TEF diagnosis was confirmed in 5 cases and TEF was suspected in 3 cases. The triple-lumen double-balloon catheter technique was employed in 5 cases, of which 4 were confirmed with H-TEF and 1 was suspected with TEF. Multidetector row spiral CT was performed in 4 cases, and 1 case was confirmed with H-TEF, while no fistula was observed in the other 3 cases. The triple-lumen double-balloon catheter technique yielded a 100% detection rate, while conventional esophagography revealed a 62.5% rate and multidetector row spiral CT showed a 25% rate. By comparative analysis, the true positive rates (TPRs) of the triple-lumen double-balloon catheter technique and conventional esophagography were not significantly different (=0.118). No significant differences were recorded in TPRs between conventional esophagography and multidetector row spiral CT (=0.221). However, the triple-lumen double-balloon catheter technique had a significantly higher TPR than multidetector row spiral CT (=0.118).

Conclusion: To diagnose congenital H-TEF in neonates, conventional esophagography is a highly valuable yet inconsistently reliable method and the diagnostic value of CT is relatively limited. The triple-lumen double-balloon catheter technique boasts a significantly valuable application for H-TEF diagnosis. Being simple, economical, and effective, it barely requires state-of-the-art facilities, and no complications have occurred during its clinical practice. These advantages justify a possible wider application of the triple-lumen double-balloon catheter technique in clinical practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9300283PMC
http://dx.doi.org/10.1155/2022/7264343DOI Listing

Publication Analysis

Top Keywords

triple-lumen double-balloon
32
double-balloon catheter
32
catheter technique
32
conventional esophagography
28
multidetector row
20
row spiral
20
technique conventional
12
esophagography
8
h-type tracheoesophageal
8
tracheoesophageal fistula
8

Similar Publications

Objective: The study aimed to analyse the detection rates of the triple-lumen double-balloon catheter technique and conventional esophagography in diagnosing H-type tracheoesophageal fistula (H-TEF) in neonates.

Methods: The data of 8 neonates diagnosed with H-TEF by surgery in the researchers' hospital between January 2015 and January 2022 were collected. We compared the detection (true positive) rates of H-TEF by the triple-lumen double-balloon catheter technique, conventional esophagography, and multidetector row spiral CT.

View Article and Find Full Text PDF

Background: Iatrogenic inferior vena cava (IVC) injury is a rare but potentially life-threatening complication during laparoscopic surgery. This experimental study aimed to assess the hemostatic ability of a new device, double balloon-equipped central venous (DB-CV) catheter, for IVC injury.

Methods: The DB-CV catheter comprises a triple-lumen sphincterotome combined with two dilating balloons having a diameter of 25 mm.

View Article and Find Full Text PDF

Introduction: Kidney procurement from donors after circulatory death (DCD) is an important part of worldwide transplantation programmes. The first kidney transplantation from DCD was successfully performed in the Czech Republic in 2002.

Method: Forty four kidneys from DCD were procured in the Transplant Centre of Pilsen between 2002 and 2015.

View Article and Find Full Text PDF

Background: Since 1999, a protocol for uncontrolled donation after cardio-circulatory death (DCD) has been carried out in our institution. We aimed at evaluating those 14 years of local experience.

Methods: We reviewed the charts of uncontrolled donors from 1999 till 2013.

View Article and Find Full Text PDF

Background: Donation after cardiac death (DCD) expands the pool of donor kidneys, but is associated with warm ischaemic injury. Two methods are used to preserve kidneys from controlled DCD donors and reduce warm ischaemic injury: in situ preservation using a double-balloon triple-lumen catheter (DBTL) inserted via the femoral artery and direct cannulation of the aorta after rapid laparotomy. The aim of this study was to compare these two techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!