Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
(), the causative agent of pneumonia (MPP), has posed a substantial burden to public health owing to a lack of rapid and effective diagnostic methods. Here, we designed a loop-mediated isothermal amplification (LAMP)-based assay, termed LAMP, combined with a nanoparticle-based lateral flow biosensor (LAMP-LFB) for rapid and sensitive diagnosis of -LAMP-LFB included a set of six primers targeting the community-acquired respiratory distress syndrome (CARDS) toxin gene and was performed optimally at 63°C for only 30 min. The resulting LAMP products could be visually indicated by LFB within 2 min, thus the whole process could be accomplished within an hour. -LAMP-LFB's sensitivity was 50 fg per reaction, which was in complete accordance with these results obtained from real-time turbidity and visual detection reagent (VDR). -LAMP-LFB had no cross-reactivity with other pathogens that had similar clinical presentations. Our assay was further validated using 100 nasopharyngeal swab samples collected from children suspected of MPP, and the result was compared with the real-time PCR method. With a positive rate of 50%, the data indicated that -LAMP-LFB is a sensitive test for detection in clinical settings. Collectively, the -LAMP-LFB assay targeting the CARDS toxin gene was a rapid, highly sensitive, and specific test that could be widely applied in point-of-care settings and basic medical facilities in rural areas.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9299420 | PMC |
http://dx.doi.org/10.3389/fcimb.2022.882855 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!