A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A deep image-to-image network organ segmentation algorithm for radiation treatment planning: principles and evaluation. | LitMetric

Background: We describe and evaluate a deep network algorithm which automatically contours organs at risk in the thorax and pelvis on computed tomography (CT) images for radiation treatment planning.

Methods: The algorithm identifies the region of interest (ROI) automatically by detecting anatomical landmarks around the specific organs using a deep reinforcement learning technique. The segmentation is restricted to this ROI and performed by a deep image-to-image network (DI2IN) based on a convolutional encoder-decoder architecture combined with multi-level feature concatenation. The algorithm is commercially available in the medical products "syngo.via RT Image Suite VB50" and "AI-Rad Companion Organs RT VA20" (Siemens Healthineers). For evaluation, thoracic CT images of 237 patients and pelvic CT images of 102 patients were manually contoured following the Radiation Therapy Oncology Group (RTOG) guidelines and compared to the DI2IN results using metrics for volume, overlap and distance, e.g., Dice Similarity Coefficient (DSC) and Hausdorff Distance (HD). The contours were also compared visually slice by slice.

Results: We observed high correlations between automatic and manual contours. The best results were obtained for the lungs (DSC 0.97, HD 2.7 mm/2.9 mm for left/right lung), followed by heart (DSC 0.92, HD 4.4 mm), bladder (DSC 0.88, HD 6.7 mm) and rectum (DSC 0.79, HD 10.8 mm). Visual inspection showed excellent agreements with some exceptions for heart and rectum.

Conclusions: The DI2IN algorithm automatically generated contours for organs at risk close to those by a human expert, making the contouring step in radiation treatment planning simpler and faster. Few cases still required manual corrections, mainly for heart and rectum.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9308364PMC
http://dx.doi.org/10.1186/s13014-022-02102-6DOI Listing

Publication Analysis

Top Keywords

radiation treatment
12
deep image-to-image
8
image-to-image network
8
treatment planning
8
algorithm automatically
8
contours organs
8
organs risk
8
algorithm
5
dsc
5
deep
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!