In this study, the application of FeO@SiO@polypyrrole-polyaniline magnetic nanocomposite was studied for Ni(ii), Cd(ii), and Pb(ii) ions preconcentration extraction. In this regard, the silica layer prevents the FeO nanoparticles (NPs) from aggregating over a broad pH range value and simultaneously improves chemical stability and hydrophilicity. By using a Box-Behnken design, the effect of various parameters affecting the preconcentration was studied. FAAS was employed to quantify the eluted analytes. The detection limits are 0.09, 1.1, and 0.3 ng mL for Ni(ii), Cd(ii) and Pb(ii), ions, respectively. The relative standard deviations (RSDs%) were calculated for determining the method's precision, lower than 7.5%. The capacities of sorption are 75, 84, and 98 mg g, respectively. With the usage of a certified reference material, the developed method was validated. After that, the validated method was employed to rapidly extract trace target ions from food samples and gave satisfactory results.