AI Article Synopsis

  • High-frequency peripheral nerve stimulation (PNS), termed "high-PAS," effectively enhances motor-evoked potentials (MEPs) and muscle functionality in both healthy individuals and patients with incomplete spinal cord injuries.
  • Data on the optimal PNS intensity for effective paired associative stimulation (PAS) is limited, prompting researchers to explore how varying PNS intensity settings impact PAS outcomes.
  • Two experiments were conducted with healthy participants, revealing that using a baseline PNS intensity (1/10 F-response persistence) or a slightly reduced intensity (25% lower) resulted in significant MEP potentiation, while higher or lower intensities did not show notable effects.

Article Abstract

Paired associative stimulation (PAS) with high-frequency peripheral nerve stimulation (PNS), called "high-PAS", induces motor-evoked potential (MEP) potentiation in healthy subjects and improves muscle activity and independence in incomplete spinal cord injury patients. Data on optimal PNS intensity in PAS are scarce. In a high-PAS protocol, PNS intensity is defined as "minimal intensity required to produce F-responses". We sought to further refine this definition and to investigate how PNS intensity affects PAS outcome. Two experiments were performed on 10 healthy subjects where MEP amplitude change was measured 0, 30, and 60 min after PAS. In the first experiment, the intensity required to achieve 7/10 persistence of F-responses was used to define PNS intensity level. In the second experiment, we used the intensity required to achieve 1/10 persistence ("baseline"). In addition, we applied this intensity at + 25%, - 25%, and - 50% levels. In the first experiment, PAS did not produce significant MEP potentiation. In the second experiment, PAS produced statistically significant MEP potentiation, with PNS intensity of "baseline" and "baseline - 25%" levels but not at + 25% or - 50% levels. In conclusion, for PAS utilizing high-frequency PNS, the intensity required to achieve 1/10 F-response persistence or the intensity 25% lower produces significant MEP potentiation in healthy subjects.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9304330PMC
http://dx.doi.org/10.1038/s41598-022-16811-1DOI Listing

Publication Analysis

Top Keywords

pns intensity
24
healthy subjects
16
mep potentiation
16
intensity required
16
intensity
12
required achieve
12
peripheral nerve
8
nerve stimulation
8
paired associative
8
associative stimulation
8

Similar Publications

Selumetinib in adults with NF1 and inoperable plexiform neurofibroma: a phase 2 trial.

Nat Med

January 2025

Pediatric Oncology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD, USA.

The MEK inhibitor selumetinib induces objective responses and provides clinical benefit in children with neurofibromatosis type 1 (NF1) and inoperable plexiform neurofibromas (PNs). To evaluate whether similar outcomes were possible in adult patients, in whom PN growth is generally slower than in pediatric patients, we conducted an open-label phase 2 study of selumetinib in adults with NF1 PNs. The study was designed to evaluate objective response rate (primary objective), tumor volumetric responses, patient-reported outcomes and pharmacodynamic effects in PN biopsies.

View Article and Find Full Text PDF
Article Synopsis
  • A new technique called high-PAS combines high-frequency peripheral nerve stimulation (PNS) and high-intensity transcranial magnetic stimulation (TMS) to potentially enhance motor function in patients with incomplete spinal cord injuries.
  • The interstimulus interval (ISI) in high-PAS allows for flexibility, making it easier to implement in clinical settings where precise timing is tough, but this also creates challenges for measuring its effectiveness.
  • Research with ten healthy participants showed that high-PAS improved motor-evoked potentials (MEPs) and significantly increased spinal excitability (measured by H-reflex amplitudes) during spinal-targeted sessions, but not in cortical-targeted sessions.
View Article and Find Full Text PDF

Aims: This study presents clinical outcomes, functional results, and return to sports after anterior cruciate ligament (ACL) reconstruction using quadruple hamstring tendon autograft or peroneus longus tendon autograft in a randomized controlled trial.

Patients And Methods: Between February 2018 and July 2019, patients who underwent ACL reconstruction were randomly assigned to two groups: hamstring and peroneus longus. Patient related outcome measurements and pain intensity were evaluated using IKDC, Lysholm, and visual analog scores at 3 and 6 months, 1, 2, and 5 years after the surgery.

View Article and Find Full Text PDF

Introduction: Dynamic modulation of grip occurs mainly within the major structures of the brain stem, in parallel with cortical control. This basic, but fundamental level of the brain, is robust to ill-formed feedback and to be useful, it may not require all the perceptual information of feedback we are consciously aware. This makes it viable candidate for using peripheral nerve stimulation (PNS), a form of tactile feedback that conveys intensity and location information of touch well but does not currently reproduce other qualities of natural touch.

View Article and Find Full Text PDF

Peripheral Nerve Stimulation Implantation Combining Ultrasound With Microendoscopy for Management of Chronic Neuropathic Pain: A Case Series Study.

Neuromodulation

December 2024

CHU de Poitiers, Predictive Research in Spine/Neuromodulation Management and Thoracic Innovation/Cardiac Surgery Lab, Poitiers, France; CHU de Poitiers, Spinal Neurosurgery, Neuromodulation & Surgery for Handicap, Poitiers, France; Université de Poitiers, Prime Institute UPR 3346, CNRS, ISAE-ENSMA, Poitiers, France.

Background: Peripheral nerve stimulation (PNS) has emerged as a minimally invasive percutaneous procedure addressing neuropathic pain. However, the percutaneous cylindrical lead ultrasound-guided implantation procedure requires expertise that limits widespread PNS utilization. To overcome these challenges, a microinvasive endoscopy device has very recently been developed, enhancing the precision of PNS implantation by providing accurate visualization of the targeted nerve.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!