A novel contact model is presented to efficiently solve a face-mask contact problem by using the finite element (FE) method for the optimized design of a custom facial mask. Simulation of contact pressure for various mask designs considering material properties of the face allows virtual evaluation of the suitability of a mask design for a person's face without conducting empirical measurement of the face-mask contact pressure. The proposed contact model is accomplished by combining three approaches to reduce the calculation cost of simulating the face-mask contact: (1) use of a simplified and modifiable mask model that applies a spline curve to design points; (2) reduction of the FE model of the face by applying static condensation; and (3) application of a contact assumption that uses the Lagrange multiplier method. A numerical case study of a medical mask design showed that the proposed model could calculate the face-mask contact pressure efficiently (0.0448 sec per design). In a pilot usability experiment, the measured contact pressure was found similar values (range of mean contact pressure: 0.0093 ~ 0.0150 MPa) to the estimated values (range of mean contact pressure: 0.0097 ~ 0.0116 MPa).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9302758 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0270092 | PLOS |
Ann Biomed Eng
January 2025
Department of Mechanical and Industrial Engineering, Northeastern University, 360 Huntington Avenue, Boston, MA, 02115, USA.
Purpose: To evaluate the population variation in head-to-helmet contact forces in helmet users.
Methods: Four different size Kevlar composite helmets were instrumented with contact pressure sensors and chinstrap tension meters. A total number of 89 volunteers (25 female and 64 male volunteers) participated in the study.
J AAPOS
January 2025
Johns Hopkins University Wilmer Eye Institute, Baltimore, Maryland. Electronic address:
Background Recommendations regarding long-term postoperative activity are intended to prevent adverse events, but no common policy or best practice exists among ophthalmologists for pediatric patients. We surveyed ophthalmologists on their postoperative guidelines after the one-month postoperative period following childhood cataract and glaucoma surgeries. Methods A 28-question anonymous Qualtrics survey was distributed via listservs and social media.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Skin Sensing Research Group, School of Health Sciences, Faculty of Environmental and Life Sciences, University of Southampton, Southampton SO17 1HE, UK.
Measuring interface pressure is currently used in a variety of settings, e.g., automotive or clinical, to evaluate pressure distribution at support surface interfaces.
View Article and Find Full Text PDFMolecules
January 2025
Department of Applied Science and Technology, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA.
Fischer-Tropsch synthesis (FTS) in a 3D-printed stainless steel (SS) microchannel microreactor was investigated using Fe@SiO catalysts. The catalysts were prepared by two different techniques: one pot (OP) and autoclave (AC). The mesoporous structure of the two catalysts, Fe@SiO (OP) and Fe@SiO (AC), ensured a large contact area between the reactants and the catalyst.
View Article and Find Full Text PDFCO flooding plays a crucial role in enhancing oil recovery and achieving carbon reduction targets, particularly in unconventional reservoirs with complex pore structures. The phase behavior of CO and hydrocarbons at different scales significantly affects oil recovery efficiency, yet its underlying mechanisms remain insufficiently understood. This study improves existing thermodynamic models by introducing Helmholtz free energy as a convergence criterion and incorporating adsorption effects in micro- and nano-scale pores.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!