Introduction: to address the challenge of inadequate and non-equitable distribution of diagnostic imaging equipment, countries are encouraged to evaluate the distribution of installed systems and undertake adequate monitoring to ensure equitability. Ghana´s medical imaging resources have been analyzed in this study and evaluated against the status in other countries.

Methods: data on registered medical imaging equipment were retrieved from the database of the Nuclear Regulatory Authority and analyzed. The equipment/population ratio was mapped out graphically for the 16 regions of Ghana. Comparison of the equipment/population ratio was made with the situation in other countries.

Results: six hundred and seventy-four diagnostic imaging equipment units from 266 medical imaging facilities (2.5 units/facility), comprising computed tomography (CT), general X-ray, dental X-ray, single-photon emission computed tomography (SPECT) gamma camera, fluoroscopy, mammography and magnetic resonance imaging (MRI) were surveyed nationally. None of the imaging systems measured above the Organization for Economic Co-operation and Development (OECD) average imaging units per million populations (u/mp). The overall equipment/population ratio estimated nationally was 21.4 u/mp. Majority of the imaging systems were general X-ray, installed in the Greater Accra and Ashanti regions. The regional estimates of equipment/population ratios were Greater Accra (49.6 u/mp), Ashanti (22.4 u/mp), Western (21.4 u/mp), Eastern (20.6 u/mp), Bono East (20.0 u/mp), Bono (19.2 u/mp), Volta (17.9 u/mp), Upper West (16.7 u/mp), Oti (12.5 u/mp), Central (11.9 u/mp), Northern (8.9 u/mp), Ahafo (8.9 u/mp), Upper East (6.9 u/mp), Western North (6.7 u/mp), Savannah (5.5 u/mp) and North-East (1.7 u/mp).

Conclusion: medical imaging equipment shortfall exist across all imaging modalities in Ghana. A wide inter-regional disparity in the distribution of medical imaging equipment exists contrary to WHO´s recommendation for equitable distribution. A concerted national plan will be needed to address the disparity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9250666PMC
http://dx.doi.org/10.11604/pamj.2022.41.301.30635DOI Listing

Publication Analysis

Top Keywords

imaging equipment
24
medical imaging
20
u/mp
17
imaging
13
diagnostic imaging
12
equipment/population ratio
12
computed tomography
8
general x-ray
8
imaging systems
8
214 u/mp
8

Similar Publications

Addressing the issues of a single-feature input channel structure, scarcity of training fault data, and insufficient feature learning capabilities in noisy environments for intelligent diagnostic models of mechanical equipment, we propose a method based on a one-dimensional and two-dimensional dual-channel feature information fusion convolutional neural network (1D_2DIFCNN). By constructing a one-dimensional and two-dimensiona dual-channel feature information fusion convolutional network and introducing a Convolutional Block Attention Mechanism, we utilize Random Overlapping Sampling Technique to process raw vibration signals. The model takes as inputs both one-dimensional data and two-dimensional Continuous Wavelet Transform images.

View Article and Find Full Text PDF

Small-scale continuum robots hold promise for interventional diagnosis and treatment, yet existing models struggle to achieve small size, precise steering, and visualized functional treatment simultaneously, termed an "impossible trinity". This study introduces an optical fiber-based continuum robot integrated imaging, high-precision motion, and multifunctional operation abilities at submillimeter-scale. With a slim profile of 0.

View Article and Find Full Text PDF

Neuromorphic-enabled video-activated cell sorting.

Nat Commun

December 2024

State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, China.

Imaging flow cytometry allows image-activated cell sorting (IACS) with enhanced feature dimensions in cellular morphology, structure, and composition. However, existing IACS frameworks suffer from the challenges of 3D information loss and processing latency dilemma in real-time sorting operation. Herein, we establish a neuromorphic-enabled video-activated cell sorter (NEVACS) framework, designed to achieve high-dimensional spatiotemporal characterization content alongside high-throughput sorting of particles in wide field of view.

View Article and Find Full Text PDF

Alzheimer's disease (AD) is a neurodegenerative ailment that is becoming increasingly common, making it a major worldwide health concern. Effective care depends on an early and correct diagnosis, but traditional diagnostic techniques are frequently constrained by subjectivity and expensive costs. This study proposes a novel Vision Transformer-equipped Convolutional Neural Networks (VECNN) that uses three-dimensional magnetic resonance imaging to improve diagnosis accuracy.

View Article and Find Full Text PDF

Background: Acute type A aortic dissection (A-AAD) with severe acute aortic regurgitation (AR) and coronary involvement is a potentially fatal condition that causes left ventricular volume overload and catastrophic acute myocardial infarction. We present the successful management of a patient using Impella 5.5 following cardiopulmonary arrest caused by A-AAD with severe acute AR and left main trunk (LMT) obstruction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!