Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
While medicinal plants are in high demand worldwide for their therapeutic properties, they can constitute a health concern to consumers when contaminated with mycotoxins. The unavailability of standardised methods for multiclass mycotoxin analysis to assess health risks has thus been realised. This study reports a simple, robust and precise method to estimate nine regulated mycotoxins in a range of Indian medicinal plant matrices including giloy (Tinospora cordifolia), ashwagandha (Withania somnifera), safed musli (Chlorophytum borivilianum), satavari (Asparagus racemosus) and tulsi (Ocimum sanctum). The sample preparation method involved extraction of homogenised matrices (12.5 g) using methanol:water (8:2, 100 mL) followed by cleanup through a multi-mycotoxin immunoaffinity column (IAC), which significantly reduced matrix interferences. The method was initially developed and validated using liquid chromatography tandem mass spectrometry (LC-MS/MS) for the simultaneous analysis of aflatoxins (B, B, G, G), ochratoxin A, zearalenone, deoxynivalenol, T-2 and HT-2 toxin. Later, it was validated using LC-fluorescence (LC-FLD) for aflatoxins, ochratoxin A and zearalenone. The optimised sample preparation protocol and analytical method provided acceptable results. Compared to LC-FLD, it was possible to attain a lower limit of quantification (LOQ) with LC-MS/MS for all the tested analytes except aflatoxins. However, LOQs of both instruments were lower than the maximum limits (MLs), with recoveries ranging between 71 and 110% and precision (RSD) of ≤10% across matrices. Despite matrix-induced signal suppressions in LC-MS/MS analysis, the matrix-matched calibrations corrected all recoveries. Considering its accuracy, reliability, robustness and time-effectiveness, this method is recommended for regulatory testing purposes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2022.463310 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!