AI Article Synopsis

  • This study reviews patients who underwent surgery at a single medical institution to assess a new way to detect pseudarthrosis using dynamic radiographs.* -
  • A traditional method relies on measuring interspinous motion (ISM) differences, while a novel angular method utilizes angles between spinous processes, avoiding the need for complicated calibrations.* -
  • The findings showed a strong correlation between the two methods, with both achieving high sensitivity and specificity for detecting pseudarthrosis confirmed by CT scans, indicating the angular method could be a reliable alternative.*

Article Abstract

Study Design: A retrospective review of operative patients at a single institution.

Objective: The aim was to validate a novel method of detecting pseudarthrosis on dynamic radiographs.

Summary Of Background Data: A common complication after anterior cervical discectomy and fusion is pseudarthrosis. A previously published method for detecting pseudarthrosis identifies a 1 mm difference in interspinous motion (ISM), which requires calibration of images and relies on anatomic landmarks difficult to visualize. An alternative is to use angles between spinous processes, which does not require calibration and relies on more visible landmarks.

Materials And Methods: ISM was measured on dynamic radiographs using the previously published linear method and new angular method. Angles were defined by lines from screw heads to dorsal points of spinous processes. Angular cutoff for fusion was calculated using a regression equation correlating linear and angular measures, based on the 1 mm linear cutoff. Pseudarthrosis was assessed with both cutoffs. Sensitivity, specificity, inter-reliability and intrareliability of angular and linear measures used postoperative computed tomography (CT) as the reference.

Results: A total of 242 fused levels (81 allograft, 84 polyetheretherketone, 40 titanium, 37 standalone cages) were measured in 143 patients (mean age 52.0±11.5, 42%F). 36 patients (66 levels) had 1-year postoperative CTs; 13 patients (13 levels) had confirmed pseudarthrosis. Linear and angular measurements closely correlated ( R =0.872), with 2.3° corresponding to 1 mm linear ISM. Potential pseudarthroses was found in 28.0% and 18.5% levels using linear and angular cutoffs, respectively. Linear cutoff had 85% sensitivity, 87% specificity; angular cutoff had 85% sensitivity, 96% specificity for detecting CT-validated pseudarthrosis. Interclass correlation coefficients were 0.974 and 0.986 (both P <0.001); intrarater reliability averaged 0.953 and 0.974 ( P <0.001 for all) for linear and angular methods, respectively.

Conclusions: The angular measure for assessing potential pseudarthrosis is as sensitive as and more specific than published linear methods, has high interobserver reliability, and can be used without image calibration.

Level Of Evidence: 3.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BRS.0000000000004375DOI Listing

Publication Analysis

Top Keywords

linear angular
12
anterior cervical
8
cervical discectomy
8
discectomy fusion
8
dynamic radiographs
8
angular
8
angular measurements
8
method detecting
8
detecting pseudarthrosis
8
spinous processes
8

Similar Publications

This study aimed to compare the dimensional alterations of the dental arches and the palate symmetry in patients with unilateral complete cleft lip and palate before and after the performance of primary surgeries by different surgical techniques. The sample was divided into Group 1, G1 - cheiloplasty (Millard technique) and single-stage palatoplasty (von Langenbeck technique); Group 2, G2 - cheiloplasty (Millard technique) and two-stage palatoplasty (Hans Pichler and Sommerlad techniques). The digital dental models were evaluated before (Time 1, T1) and after (Time 2, T2) primary surgeries.

View Article and Find Full Text PDF

Metrology with a twist: probing and sensing with vortex light.

Light Sci Appl

January 2025

School of Physics, University of the Witwatersrand, Private Bag 3, Johannesburg, 2050, South Africa.

Optical metrology is a well-established subject, dating back to early interferometry techniques utilizing light's linear momentum through fringes. In recent years, significant interest has arisen in using vortex light with orbital angular momentum (OAM), where the phase twists around a singular vortex in space or time. This has expanded metrology's boundaries to encompass highly sensitive chiral interactions between light and matter, three-dimensional motion detection via linear and rotational Doppler effects, and modal approaches surpassing the resolution limit for improved profiling and quantification.

View Article and Find Full Text PDF

Objective: The study compares and evaluates planned virtual outcomes with actual post-treatment outcomes to assess the accuracy and predictability of clinical results during presurgical infant orthopaedics (PSIO) with AlignerNAM in infants with unilateral cleft lip and palate.

Setting: Institutional study.

Participants: 14 UCLP patients.

View Article and Find Full Text PDF

Orbital angular momentum of single photons: revealing quantum fundamentals.

Philos Trans A Math Phys Eng Sci

December 2024

School of Physics and Astronomy, The University of Glasgow, Glasgow, G12 8QQ, UK.

In 1992, Allen . (Allen L, Beijersbergen MW, Spreeuw RJC, Woerdman JP. 1992 Orbital angular momentum of light and the transformation of Laguerre-Gaussian laser modes.

View Article and Find Full Text PDF

Introduction: The dynamic navigation system (DNS) in endodontics presents a significant learning curve. This cross-sectional study aimed to assess the number of cases required to achieve consistent performance in DNS-assisted treatment of maxillary anterior teeth with pulp canal calcification.

Methods: A series of DNS procedures were performed on 45 calcified maxillary anterior teeth with pulp necrosis by a single endodontist who had no prior clinical DNS experience.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!