Paediatric gonad shielding in pelvic radiography: A systematic review and meta-analysis.

Radiography (Lond)

University of Leeds School of Medicine, Worsley Building, Woodhouse, Leeds, LS2 9JT, UK.

Published: November 2022

Introduction: The British Institute of Radiology (BIR) and American Association of Physicists in Medicine (AAPM) have recommended that gonad shielding is no longer used during pelvic X-ray examinations. The BIR guidance states that shielding may still be considered for use on males, but should not be used on females. This paper aimed to evaluate if this decision was supported by evidence from practice, by comparing the accuracy of gonad shield placement in paediatric males and females.

Methods: A systematic review of databases including EMBASE, MEDLINE and PubMed was performed in February 2021. Studies were considered eligible if they provided data on the use of gonad shielding during pelvic X-ray examinations on male and female patients under the age of 18. Nine studies met the inclusion criteria and data extraction was performed. Quality appraisal was undertaken, and a meta-analysis of shielding accuracy was performed on seven studies.

Results: The results from the meta-analysis (2187 total radiographs) demonstrated that female patients were significantly more likely (OR 1.38, 95% CI 0.88-1.87) than males to have gonad shields placed inaccurately (p value < 0.001).

Conclusion: Gonad shield placement on paediatric female patients is significantly less accurate than on males, and so the results support the AAPM and BIR guidance to stop the practice for females. Shield application may also be frequently inaccurate for males, but the review does not provide clear evidence for or against continuing the practice for males.

Implications For Practice: Discontinuing the use of gonad shields in paediatric pelvic radiography on female patients is supported. Any continued use on male patients, or for reasons such as psychological reassurance, should be subject to enhanced training and audit to ensure benefits outweigh any risks.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radi.2022.06.009DOI Listing

Publication Analysis

Top Keywords

gonad shielding
12
shielding pelvic
8
systematic review
8
pelvic x-ray
8
x-ray examinations
8
female patients
8
shielding
5
paediatric gonad
4
pelvic radiography
4
radiography systematic
4

Similar Publications

Simulation of the shielding effect of lead apron undergoing chest CT scan.

Radiat Prot Dosimetry

November 2024

Institute of Radiation Medicine, Fudan University, 2094 Xietu Road, Shanghai 200032, China.

Lead aprons are used to reduce radiation dose to patients. As the distance between the lead apron and the edge of the scan range increases, organ dose is expected to decrease, but with increasing scattered radiation dose in the body. By simulation, this work aims at estimate whether the organ dose increases due to the scattered radiation in the body with lead apron.

View Article and Find Full Text PDF

A Paradigm Shift From Having Dental Patient Shielding to No Patient Shielding?

Int Dent J

October 2024

Oral and Maxillofacial Radiology, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China. Electronic address:

View Article and Find Full Text PDF

[Clinical characteristics and management status of Turner syndrome in 1 089 children].

Zhonghua Er Ke Za Zhi

October 2024

Department of Pediatrics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology (HUST), Hubei Key Laboratory of Pediatric Genetic Metabolic and Endocrine Rare Diseases, Wuhan 430030, China.

To investigate the clinical characteristics and management status of children with Turner syndrome (TS) in China. As a cross-sectional study, 1 089 TS patients were included in the database of the National Collaborative Alliance for the Diagnosis and Treatment of Turner Syndrome from August 2019 to November 2023. Clinical characteristics (growth development, sexual development, organ anomalies, etc.

View Article and Find Full Text PDF

Examining the Effects of a Narrative-Based Educational Animation for Radiology Technologists About Discontinuing Gonadal Shielding.

J Am Coll Radiol

September 2024

Department of Art as Applied to Medicine, The Johns Hopkins University School of Medicine, Baltimore, Maryland; The Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland. Electronic address:

View Article and Find Full Text PDF

The role of immune cell death in spermatogenesis and male fertility.

J Reprod Immunol

September 2024

Dongguan Key Laboratory of Stem Cell and Regenerative Tissue Engineering, The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan, China. Electronic address:

The male reproductive system provides a distinctive shield to the immune system, safeguarding germ cells (GCs) from autoimmune harm. The testis in mammals creates a unique immunological setting due to its exceptional immune privilege and potent local innate immunity. which can result from a number of different circumstances, including disorders of the pituitary gland, GC aplasia, and immunological elements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!