Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Engineering of the Carpentier-Edwards Physio (PR-I) and Physio II (PR-II) rings (Edwards Lifesciences Corp., Irvine, CA, USA) combines flexibility with remodeling. PR-II is considered an improvement of PR-I, as it boasts of an improved shape, a double saddle, and a sewing cuff that reduces tension on sutures. Beyond the superior effect of the PR-II on the annular physiology, it has not been proven to be clinically better than the PR-I. This study compares the long-term clinical outcomes of MV repair for degenerative disease with these rings.
Methods: From 2004 to 2020, MV repair with Physio ring annuloplasty (group PR-I) was performed in 231 patients, and with Physio-II ring annuloplasty (group PR-II) in 255 patients. A propensity score-matching analysis was used to pair 104 in each group. Primary outcome was recurrent MR≥3 and secondary outcomes were long-term survival, cardiac death, and MV-related events (MVREs). The 15-year follow-up data were complete in 97.3% of patients.
Results: There were no differences in 15-year freedom from recurrent MR (P=0.721), survival and cardiac death between the matched groups (P=0.693 and P=0.135, respectively). MVREs, including cardiac death, pacemaker implantation, thromboembolism, bleeding, and reoperation were also similar between the matched groups (P=0.603). However, 5-year recurrent MR was significantly higher in PR-I than in PR-II (P=0.010). Multivariate analysis showed Barlow's disease and preoperative MR≥3 as risk factors for late MR recurrence.
Conclusions: Type of annuloplasty rings did not influence long-term clinical outcomes. Better annular dynamics seen in PR-II annuloplasty does not translate into superior freedom from recurrent MR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.23736/S0021-9509.22.11874-4 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!