Purpose: Optimal management of patients with prostate cancer (PCa) to achieve bowel and bladder reproducibility for radiation therapy (RT) and the appropriate planning target volume (PTV) expansions for use with modern image guidance is uncertain. We surveyed American Society of Radiation Oncology radiation oncologists to ascertain practice patterns for definitive PCa RT with respect to patient instructions and set up, daily image guidance, and subsequent PTV expansions.

Methods And Materials: A pattern of practice survey was sent to American Society of Radiation Oncology radiation oncologists who self-identified as specializing in PCa. Respondents identified the fractionation regimens routinely used, and their practices regarding diet, bowel, and bladder instructions for patients with PCa before RT simulation and throughout treatment. Questions regarding PTV margins, daily set up practices, and use of image guidance were included.

Results: Of 190 respondents, 158 reported using conventional fractionation (CFx), 49 moderate hypofractionation (MHFx), and 61 stereotactic body radiation therapy (SBRT). Diet modifications during RT were advised by 84% of respondents, treatment with full bladder by 96%, and bowel instructions by 78%. Prescription of bowel medication was higher for respondents using SBRT (95.1%) versus those using CFx/MHFx (55.1%; 34.7%). The most common implantable device reported was fiducial markers, with increased use in SBRT (86.0%; 68.9%) versus CFx/MHFx. Cone beam computed tomography was the most common daily imaging technique across fractionation regimens. SBRT showed correlation between PTV margin expansions, fiducial marker use, and image guidance.

Conclusions: Survey results indicate heterogeneity in treatment modality, dose, patient instructions, and PTV expansions used by radiation oncologists in the treatment of patients with PCa. Further investigation to define appropriate patient instructions on bowel preparation to maximize target reproducibility in PCa is needed, as is continued guidance on evidence-based approaches for image guidance and PTV margin selection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9280021PMC
http://dx.doi.org/10.1016/j.adro.2022.100902DOI Listing

Publication Analysis

Top Keywords

image guidance
16
bowel bladder
12
radiation therapy
12
radiation oncologists
12
patient instructions
12
bladder reproducibility
8
radiation
8
prostate cancer
8
practice survey
8
ptv expansions
8

Similar Publications

Purpose: To use imaging data from stereotactic MR-guided online adaptive radiotherapy (SMART) of ultracentral lung tumors (ULT) for development of a safe non-adaptive approach towards stereotactic body radiotherapy (SBRT) of ULT.

Patients And Methods: Analysis is based on 19 patients with ULT who received SMART (10 × 5.0-5.

View Article and Find Full Text PDF

There is a crucial need to more deeply understand the impact and etiology of bias toward persons with developmental disabilities (PWDD). A largely unstudied area of concern and possible intervention is the portrayal of PWDD in medical education. Often, medical photographs portray PWDD with obscured faces, emotionless, and posed in an undignified way.

View Article and Find Full Text PDF

Study Objective: We present the results of the first feasibility and safety study of a novel multi-modality falloposcope, in 19 volunteers. The falloposcope incorporated multispectral fluorescence imaging (MFI) and optical coherence tomography (OCT) for evaluation of the fallopian tubes (FT).

Methods: Nineteen females undergoing elective salpingectomy were recruited in this IRB-approved study.

View Article and Find Full Text PDF

The formula-based estimation of the right internal jugular venous (IJV) catheterization depth can be inaccurate when using ultrasound guidance. External landmark-based and radiological landmark-based methods have been proposed as alternatives to estimate the insertion depth. This study aimed to evaluate these methods using transesophageal echocardiography (TEE)-guided insertion depth as the reference.

View Article and Find Full Text PDF

We developed an AI system capable of automatically classifying anterior eye images as either normal or indicative of corneal diseases. This study aims to investigate the influence of AI's misleading guidance on ophthalmologists' responses. This cross-sectional study included 30 cases each of infectious and immunological keratitis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!