Primeval outcomes of thoracoscopic transmitral myectomy with anterior mitral leaflet extension for hypertrophic obstructive cardiomyopathy.

J Card Surg

Department of Cardiovascular Surgery, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Guangzhou, China.

Published: October 2022

Background: The transaortic Morrow procedure is the current gold standard for hypertrophic obstructive cardiomyopathy (HOCM) patients who are resistant to maximum drug therapy. It is controversial whether concomitant mitral valve intervention is necessary. Only a few centers apply for concomitant anterior mitral leaflet extension with a bovine or autologous pericardial patch to further decrease systolic anterior motion. Our aim is to assess the primeval outcomes of thoracoscopic transmitral myectomy with anterior mitral leaflet extension (TTM-AMLE) in symptomatic HOCM patients.

Methods: Between April 2019 and November 2020, 18 consecutive HOCM patients who underwent TTM-AMLE were enrolled in this study. Preoperative, postoperative, and follow-up outcomes were compared and statistically analyzed.

Results: The mean age was (50.17 ± 6.18) years and 10 (55.56%) were males. 18 (100%) patients had mitral regurgitation preoperatively, and they all successfully underwent TTM-AMLE with a median cardiopulmonary bypass and aortic cross-clamp time of 200.0 (150.8, 232.0), and 127.5 (116.0, 149.0) min, respectively. The median length of ICU stay was 2.7 (1.4, 5.2) days. The interventricular septum thickness was significantly reduced (from 18.03 ± 3.02 mm to 11.91 ± 1.66 mm, p < .001). There was no perioperative mortality, perforation of ventricular septum, or conversion to sternotomy observed. During a median follow-up of 18 months (IQR, 5-24 months), 1 (5.56%) patient had severe mitral regurgitation due to patch detachment and received reoperation. Moderate degree of mitral regurgitation and more than 50 mmHg in left ventricular outflow tract gradient were found in 2 (11.11%), and 1 (5.56%) patients, respectively. 1 (5.56%) patient who had second-degree atrioventricular block received permanent pacemaker implantation postoperatively. Overall, the maximum left ventricular outflow tract gradient (88.50 [59.50, 112.75] mmHg vs. 10.50 [7.00, 15.50] mmHg, p = .002), left ventricular outflow tract velocity (4.70 [3.86, 5.33] m/s vs. 1.60 [1.33, 1.95] m/s, p < .001) and the degree of mitral regurgitation (6.99 ± 4.47 cm vs. 2.22 ± 1.51 cm , p = .001) were significantly decreased, with a significant reduction in the proportion of systolic anterior motion (94.44% vs. 16.67%, p < .001).

Conclusions: The TTM-AMLE is a safe and effective surgical approach for selected patients with HOCM. In our series, it provides excellent relief of left ventricular outflow tract obstruction, while significantly eliminating mitral regurgitation. The early outcomes of TTM-AMLE are satisfactory, but further studies and longer follow-ups are awaited.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jocs.16773DOI Listing

Publication Analysis

Top Keywords

anterior mitral
12
mitral leaflet
12
leaflet extension
12
primeval outcomes
8
outcomes thoracoscopic
8
thoracoscopic transmitral
8
transmitral myectomy
8
myectomy anterior
8
hypertrophic obstructive
8
obstructive cardiomyopathy
8

Similar Publications

A New, Easy-to-Learn, Fear-Free Method to Stop Purring During Cardiac Auscultation in Cats.

Animals (Basel)

January 2025

Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, 3584 CM Utrecht, The Netherlands.

Background: Purring in cats can interfere with cardiac auscultation. If the produced noise is loud enough, purring makes it impossible to perform a meaningful auscultation as it is much louder than heart sounds and murmurs. Our study introduced and tested a new, simple, fear-free, cat-friendly method to stop purring during auscultation.

View Article and Find Full Text PDF

Donation after circulatory death is helping to expand the donor pool for heart transplantation. Nevertheless, these hearts are more susceptible to myocardial edema and decision of accepting the organ can be a challenge for the heart transplant team. Hemodynamic and echocardiographic criteria are used routinely, but there is still a lack of strong evidence that supports the decision-making in particular situations.

View Article and Find Full Text PDF

Background: Treatment of residual mitral regurgitation (MR) with different percutaneous devices after transcatheter edge-to-edge repair (TEER) has been reported as an alternative option to reclipping or surgery. This review aims at describing the different transcatheter strategies available and their results when managing residual MR after TEER.

Methods: A literature search was undertaken across Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane library databases, to identify article reporting patients with post-TEER residual MR managed by a transcatheter approach that did not involve only the implantation of new clips.

View Article and Find Full Text PDF

Rationale: Cardiac papillary fibroelastoma (CPF) is a rare cardiac tumor that can lead to severe and potentially fatal complications such as stroke, myocardial infarction, and sudden cardiac death. The rarity of CPF makes it challenging for clinicians to diagnose and treat, highlighting the importance of timely and accurate diagnosis to prevent catastrophic outcomes. This case report aims to contribute to the clinical understanding of CPF involving the mitral valve (MV), providing insights into diagnosis and treatment strategies.

View Article and Find Full Text PDF

A tailored substrate-based approach using focal pulsed field catheter ablation in patients with atrial fibrillation and advanced atrial substrate: Procedural data and 6-months success rates.

Heart Rhythm

January 2025

Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Maastricht, The Netherlands; Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark. Electronic address:

Background: Focal pulsed-field ablation (F-PFA) integrated in electroanatomical mapping (EAM) systems allows tailored lesion sets in patients with atrial fibrillation (AF).

Objective: To determine feasibility, safety and 6-months outcome of F-PFA for a tailored substrate-based catheter ablation (CA) approach in patients with AF and advanced atrial substrate.

Methods: Consecutive patients with AF and advanced atrial substrate treated by a F-PFA system (Cardiofocus) through contact-force sensing catheters integrated in EAM systems were prospectively enrolled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!