In the transcatheter aortic valve implantation (TAVI) era, the indications for balloon aortic valvuloplasty (BAV) are increasing. Previously, the INOUE-BALLOON® (IB) was used only for antegrade BAV, but recently, it has also been used for retrograde BAV. However, the safety and feasibility of retrograde BAV using an IB are not fully understood. In this study, we investigated the safety and feasibility of retrograde BAV using an IB in elderly Japanese patients with severe aortic stenosis (AS). We compared 39 cases of retrograde BAV using an IB performed from June 2018 to September 2020 and 34 cases of antegrade BAV using an IB performed from August 2013 to May 2018. The total number of complications was lower in retrograde BAV than in antegrade BAV (p = 0.020). The procedure time was significantly shorter in retrograde BAV than in antegrade BAV (p < 0.001), and the maximum balloon size and number of balloon inflations were smaller in retrograde BAV than in antegrade BAV (p = 0.002 and p < 0.001, respectively). There was no significant difference in the degree of improvement in the aortic valve area or ejection fraction between retrograde and antegrade BAV. In conclusion, the present study showed the safety and feasibility of retrograde BAV using an IB in elderly Japanese patients with severe AS compared with antegrade BAV using an IB.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00380-022-02120-0DOI Listing

Publication Analysis

Top Keywords

retrograde bav
24
antegrade bav
16
safety feasibility
12
feasibility retrograde
12
bav
11
balloon aortic
8
aortic valvuloplasty
8
severe aortic
8
aortic stenosis
8
bav performed
8

Similar Publications

Efficacy and safety of a minimalistic balloon aortic valvuloplasty strategy in a centre without heart surgery.

AsiaIntervention

February 2024

Cardiology Department, Ospedale Maggiore, Bologna, Italy and Azienda USL di Bologna, Bologna, Italy.

Background: Balloon aortic valvuloplasty (BAV) is a palliative tool for patients with symptomatic severe aortic stenosis (AS) at prohibitive risk for surgery or as a bridge to surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR). BAV is traditionally performed in hospitals with onsite cardiac surgery due to its potential complications.

Aims: The aim of this study was to evaluate the safety of BAV procedures performed by trained high-volume operators in a centre without onsite surgery and to assess the effect of a minimalistic approach to reduce periprocedural complications.

View Article and Find Full Text PDF

Impact of Variation in Commissural Angle between Fused Leaflets in the Functionally Bicuspid Aortic Valve on Hemodynamics and Tissue Biomechanics.

Bioengineering (Basel)

October 2023

Congenital Valve Procedural Planning Center, Department of Pediatric Cardiology and Division of Pediatric Cardiac Surgery, Cleveland Clinic Children's, and The Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, OH 44195, USA.

In subjects with functionally bicuspid aortic valves (BAVs) with fusion between the coronary leaflets, there is a natural variation of the commissural angle. What is not fully understood is how this variation influences the hemodynamics and tissue biomechanics. These variables may influence valvar durability and function, both in the native valve and following repair, and influence ongoing aortic dilation.

View Article and Find Full Text PDF

Right coronary artery originating from the left ventricular outflow tract diagnosed after a Ross procedure: a case report.

Eur Heart J Case Rep

July 2022

Division of Cardiology, Department of Medicine, Ahmanson-UCLA Adult Congenital Heart Disease Center, David Geffen School of Medicine, University of California, Los Angeles, 200 Medical Plaza, Suite 202, Los Angeles, CA 90095, USA.

Background: Anomalous coronary origin from the left ventricular outflow tract (LVOT) is an exceedingly rare condition thought to be associated with the bicuspid aortic valve (BAV). While the malignant presentation of this entity has been described, its pathophysiology and diagnostic evaluation are poorly understood.

Case Summary: A 33-year-old woman status post Ross procedure in childhood for congenital aortic stenosis due to BAV with presumed common origin of right and left coronary arteries based on single coronary ostium seen on aortic valve inspection, presented with symptomatic pulmonary regurgitation and stenosis.

View Article and Find Full Text PDF

In the transcatheter aortic valve implantation (TAVI) era, the indications for balloon aortic valvuloplasty (BAV) are increasing. Previously, the INOUE-BALLOON® (IB) was used only for antegrade BAV, but recently, it has also been used for retrograde BAV. However, the safety and feasibility of retrograde BAV using an IB are not fully understood.

View Article and Find Full Text PDF

Balloon aortic valvuloplasty (BAV) was developed as a technique to treat aortic stenosis (AS) and is associated with significant improvements in aortic valve area and trans-aortic valve gradient in the early and immediate periods after the procedure. BAV is commonly performed using a trans-femoral retrograde approach; however, trans-femoral access is associated with frequent access-site bleeding. Among 146 patients with symptomatic severe AS who were treated with BAV in our institution, 123 patients received BAV treatment via a trans-radial approach using a 7-Fr Glidesheath.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!