Purpose: The optimal way to stabilize intra-articular distal radius fractures is unclear despite recent advances in surgical management. Volar plating is the most common treatment but may not be sufficient for more complex intra-articular AO type C fractures. The purpose of this randomized controlled study was to evaluate the radiographic and clinical outcomes following surgical treatment of AO type C distal radius fractures, comparing volar with combined plating.

Methods: In this study, 150 patients were randomized to volar locking plate (n = 75) or combined plating (n = 75) following a distal radius fracture AO type C. The 1-year follow-up included radiographic outcome (Batra score), visual analog scale pain score, hand grip strength, wrist range of motion, Patient-Rated Wrist Evaluation score, and Quick Disabilities of the Arm, Shoulder, and Hand score.

Results: Overall, 147 patients (median age 61 years) completed the 1-year follow-up (73 patients with volar plate and 74 with combined plating). No difference was found in radiographic outcome between the treatment groups. The volar plate group had significantly better Patient-Rated Wrist Evaluation scores, Quick Disabilities of the Arm, Shoulder, and Hand scores, hand grip strength, visual analog scale scores during activity, and flexion, extension, ulnar and radial deviation than the combined plate group. Hardware removal was performed in 10% in the volar plate group and in 31% in the combined plate group. There was no postoperative infection in the volar plate group but 3 cases in the combined plate group.

Conclusions: In patients with complex AO type C intra-articular fractures, volar and combined plating yielded the same radiographic result. The differences in Patient-Rated Wrist Evaluation and Quick Disabilities of the Arm, Shoulder, and Hand scores between the groups did not reach the thresholds for minimal clinically important differences, suggesting similar clinical outcome. The combined plating group had a considerably higher frequency of hardware removal and postoperative infections.

Type Of Study/level Of Evidence: Therapeutic I.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2022.04.018DOI Listing

Publication Analysis

Top Keywords

combined plating
20
plate group
20
distal radius
16
volar plate
16
radius fractures
12
patient-rated wrist
12
wrist evaluation
12
quick disabilities
12
disabilities arm
12
arm shoulder
12

Similar Publications

Along with the rapid development of the digital economy and artificial intelligence, heat sinks available for immersion phase-change liquid cooling (IPCLC) of chips are facing huge challenges. Here, we design a high-performance IPCLC heat sink based on a copper microgroove/nanocone (MGNC) composite structure. Maximal heat fluxes () of the MGNC structure, microgroove structure, and flat copper reach 112.

View Article and Find Full Text PDF

Automated High-Throughput Affinity Capture-Mass Spectrometry Platform with Data-Independent Acquisition.

J Proteome Res

January 2025

Discovery Research, AbbVie, Inc., 1 North Waukegan Rd., North Chicago, Illinois 60064, United States.

Affinity capture (AC) combined with mass spectrometry (MS)-based proteomics is highly utilized throughout the drug discovery pipeline to determine small-molecule target selectivity and engagement. However, the tedious sample preparation steps and time-consuming MS acquisition process have limited its use in a high-throughput format. Here, we report an automated workflow employing biotinylated probes and streptavidin magnetic beads for small-molecule target enrichment in the 96-well plate format, ending with direct sampling from EvoSep Solid Phase Extraction tips for liquid chromatography (LC)-tandem mass spectrometry (MS/MS) analysis.

View Article and Find Full Text PDF

Background: Liver fibrosis is a serious global health issue, but current treatment options are limited due to a lack of approved therapies capable of preventing or reversing established fibrosis.

Aim: This study investigated the antifibrotic effects of a synthetic peptide derived from α-lactalbumin in a mouse model of thioacetamide (TAA)-induced liver fibrosis.

Methods: analyses were conducted to assess the physicochemical properties, pharmacophore features, and docking interactions of the peptide.

View Article and Find Full Text PDF

Therapeutic effect of titanium locking plate combined with suture anchor repair in proximal humeral fractures.

Pak J Med Sci

January 2025

Zhenfeng Huang Department of Orthopedic Trauma, Wuhan Fourth Hospital, Wuhan, Hubei Province 430000, P.R. China.

Objective: To explore the therapeutic effect of titanium locking plate combined with suture anchor (SA) repair in the treatment of proximal humeral fractures (PHF).

Methods: This retrospective study was conducted by analyzing the clinical data of 113 patients with PHF admitted to Wuhan Fourth Hospital from March 2021 to October 2023. Among them, 55 patients underwent open reduction and internal fixation (OR/IF) using titanium locking plate (OR/IF group), and 58 patients underwent surgery with titanium locking plate combined with SA (SA group).

View Article and Find Full Text PDF

Purpose: To compare the efficacy and safety of skip titanium plates combined with adjacent spinous process suture suspension versus continuous titanium plate fixation in cervical laminoplasty.

Methods: A retrospective analysis of 125 patients (62 men, 63 women, average age 60.9 ± 10.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!