Background: Management of posterolateral tibial plateau quadrant fractures can be challenging, and two posterior approaches were frequently used for exposure, reduction, and fixation: posterolateral approach and posteromedial approach. The purpose of this study was to compare their deep anatomical structure and analyze their limits and the risk of injury to important structures during surgical dissection of two approaches.
Method: Five lower limb specimens were used in this study. After dissection of the skin and superficial fascia of each specimen, deep structures were dissected via posteromedial and posterolateral approach, and several parameters including perpendicular distance from the anterior tibial artery coursing through the interosseous membrane fissure to the lateral joint line and apex of fibular head and so on were measured and analyzed.
Result: The perpendicular distance from the ATA coursing through the interosseous membrane fissure to the lateral joint line was 49.3 ± 5.6 mm (range 41.3-56.7 mm), while the distance to the apex of fibular head was 37.7 ± 7.2 mm (range 29.0-48.0 mm). The transverse distance of the anterior tibial vascular bundle is around 10 mm. The perpendicular distance from the top accompanying vein of the ATA bundle to lateral joint line and apex of fibular head was 44.1 ± 6.3 mm and 32.5 ± 7.6 mm, respectively. The maximum proportion of posterolateral tibial plateau shielded by the fibular head from the posterior view was 61.7 ± 4.9% (range 55.6-64.1%). The average length of popliteus muscle outside the joint was 83.1 ± 6.0 mm (range 76.5-92.2 mm), and the width in the middle was 28.1 ± 4.3 mm (range 26.6-29.1 mm).
Conclusion: Although posterolateral approach seems more direct for exposure of posterolateral quadrant tibial plateau fracture, it has three major disadvantages in deep dissection. Posteromedial approach through the medial board of medial head of gastrocnemius-soleus may be safer, but it was hard for direct visualization of articular surface which limits it usage for only a few cases.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9284737 | PMC |
http://dx.doi.org/10.1186/s13018-022-03236-9 | DOI Listing |
Ann Plast Surg
December 2024
From the Department of Hand and Foot Surgery, The Second Affiliated Hospital of Soochow University, Suzhou, China.
Background: Complex lower extremity defects are difficult to cover and often require multiple free tissue transfers. Chimeric anterolateral thigh free flaps (ALTF) and peroneal artery perforator free flaps (PAPF) have been designed specifically as an alternative for reconstruction with arterial end-to-side (ETS) anastomosis. We aimed to assess our institutional experience with this technique and to define its role in complex lower extremity reconstruction.
View Article and Find Full Text PDFJ Orthop Surg Res
December 2024
Department of Orthopaedic Trauma, Hebei Medical University Third Hospital, Ziqiang Road No.139, Shijiazhuang, Hebei Province, 050051, China.
Background: Posttraumatic osteoarthritis (PTOA) is directly associated with early acute articular cartilage injury. Inhibition of cartilage destruction immediately following joint damage can effectively slow or prevent PTOA progression. Therefore, we sought to determine intervention targets and therapeutic strategies in the acute stage of cartilage injury.
View Article and Find Full Text PDFBMC Musculoskelet Disord
December 2024
Department of Orthopaedics and Traumatology, The First Affiliated Hospital of Zhejiang Chinese Medical University, 54 Youdian Road, Shangcheng District, Hangzhou, 310006, China.
Background: This study evaluated the clinical effects of the use of a temporary bi-frame fixator in conjunction with minimally invasive percutaneous plate osteosynthesis (MIPPO) for treating AO/OTA 41B3 and 41C tibial plateau fractures (TPFs).
Methods: This was a retrospective analysis of 30 patients with TPFs affected by vertical compression seen from October 2019 to October 2020. All patients were treated with a bi-frame fixator to correct the vertical shortening deformity, with the MIPPO technique used after reduction.
Injury
December 2024
Department of Orthopaedics, Larnaca General Hospital, State Health Services Organisation, Larnaca, Cyprus.
The purpose of this study was to establish typical dose values at orthopaedic operating rooms of the Larnaca General Hospital (LGH). Kerma area product (KAP), fluoroscopy time (FT) and cumulative air-kerma (K) measurements were collected for 821 patients who underwent common and reproducible trauma surgery over a five-year period, with three mobile C-arm systems; two equipped with an image-intensifier and one with a flat-panel detector. Dose indices were automatically extracted from radiation dose structured reports or DICOM meta-data files archived in the PACS, using custom-made software.
View Article and Find Full Text PDFCureus
November 2024
Anesthesiology, Unidade Local de Saúde do Alentejo Central, Évora, PRT.
Epidural abscess is a rare complication of neuraxial techniques, which, when left unnoticed, can lead to significant neurological deficits and poor outcomes. Identification of patients at high risk and the conduct of a strict aseptic technique are some of the measures that play an important role in epidural abscess prevention. Prompt recognition and treatment of epidural abscesses are essential.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!