A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a validated high-performance thin-layer chromatography method for quantification of lupeol from different parts of Bauhinia acuminata. | LitMetric

Development of a validated high-performance thin-layer chromatography method for quantification of lupeol from different parts of Bauhinia acuminata.

Biomed Chromatogr

Medicinal and Natural Products Research Laboratory, Department of Pharmaceutical Sciences and Technology, Institute of Chemical Technology, Mumbai, Maharashtra, India.

Published: October 2022

The goal of the study was to determine how much lupeol was present in different Bauhinia acuminata samples. Lupeol was analyzed using a unique (verified) high-performance thin-layer chromatography (HPTLC) method. Separation of various compounds was achieved on silica gel (66 F 254) plates with toluene and methanol (99:1) as the mobile phase, followed by derivatization with Liebermann-Burchard reagent (r  = 0.996). The proposed approach demonstrated a satisfactory linear relationship in the concentration range of 4-8 μg/mL. The limit of detection and limit of quantification were 63.84 ng/spot and 208.57 ng/spot, respectively. The proposed method was a simple and precise procedure that provided good resolution with other constituents of extracts. The validated HPTLC method described was simple, dependable, and practical and could be useful for standardizing and evaluating the quality of herbal material and formulations containing various Bauhinia species. The leaf, stem, unsaponified matter leaf, and stem petroleum ether extract had good amounts of lupeol (25.75, 38.25, 1.65, and 1.75, respectively). This research will be helpful for the quantitative determination of lupeol from herbal formulations as well as useful for further studies in this area.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bmc.5448DOI Listing

Publication Analysis

Top Keywords

high-performance thin-layer
8
thin-layer chromatography
8
bauhinia acuminata
8
hptlc method
8
leaf stem
8
lupeol
5
development validated
4
validated high-performance
4
method
4
chromatography method
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!