Magnesium alloys are an ideal material for biodegradable vascular stents, which can be completely absorbed in the human body, and have good biosafety and mechanical properties. However, the rapid corrosion rate and excessive localized corrosion, as well as challenges in the preparation and processing of microtubes for stents, are restricting the clinical application of magnesium-based vascular stents. In the present work we will give an overview of the recent progresses on biodegradable magnesium based vascular stents including magnesium alloy design, high-precision microtubes processing, stent shape optimisation and functional coating preparation. In particular, the Triune Principle in biodegradable magnesium alloy design is proposed based on our research experience, which requires three key aspects to be considered when designing new biodegradable magnesium alloys for vascular stents application, i.e. biocompatibility and biosafety, mechanical properties, and biodegradation. This review hopes to inspire the future studies on the design and development of biodegradable magnesium alloy-based vascular stents.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9255809 | PMC |
http://dx.doi.org/10.12336/biomatertransl.2021.03.06 | DOI Listing |
Sci Rep
January 2025
Department of Cardiology, University of Galway, University Road, Galway, H91 TK33, Ireland.
Diffuse coronary artery disease (CAD) impacts the immediate hemodynamic and clinical outcomes of percutaneous coronary intervention (PCI). We evaluated whether the diffuse pattern of CAD derived from angiographic Quantitative flow ratio (QFR) impacts the immediate hemodynamic outcome post-PCI and the medium term predicted vessel-oriented composite endpoint (VOCE). Paired pre-procedure QFRs were assessed in 503 patients and 1022 vessels in the Multivessel TALENT (MVT) trial.
View Article and Find Full Text PDFJ Thorac Cardiovasc Surg
January 2025
Department of Surgery, Division of Vascular Surgery, University of Maryland School of Medicine.
Objective: We present our experience with endovascular Bentall procedure (Endo-Bentall) using a modular valve conduit (Endo-Bentall) in high-risk patients with aortic root pathologies.
Methods: The physician constructed Endo-Bentall device is composed of a self-expanding transcatheter aortic valve (TAVR), aortic endovascular stent graft (TEVAR), and two wire-reinforced fenestrations for coronary artery stenting. The TAVR valve is sutured into an appropriately sized TEVAR graft.
Eur J Vasc Endovasc Surg
January 2025
Academic Department of Vascular Surgery, Section of Vascular Risk and Surgery, St. Thomas' Hospital, London, UK.
Introduction: In 2015, Society for Vascular Surgery guidelines on claudication management were released spanning optimal medical management, procedural, and post-procedure recommendations. Uptake of guidelines and changes to clinical practice over time remain unknown. This study hypothesized that guideline aligned practice increased after guideline release.
View Article and Find Full Text PDFIndian J Thorac Cardiovasc Surg
February 2025
Department of CTVS, AIIMS, Jodhpur, 342005 India.
Carotid artery stenting (CAS) has become a favoured alternative to surgical carotid endarterectomy (CEA) in select cases of critical internal carotid artery (ICA) occlusion. However, complications such as stent migration or entrapment can occur, necessitating prompt diagnosis and intervention. We present a case of a 75-year-old diabetic male who underwent CAS for recurrent presyncope at a private hospital, and during the procedure of CAS the stent was migrated and its proximal part was impacted in the critically narrowed part of the ICA.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!