A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluating the intensity of the 'prompt' 140.5 keV γ-ray of Mo using a 4παβ(LS)-γ(HPGe) measurement system. | LitMetric

The absolute intensity for the 'prompt' 140.5 keV gamma-ray of Mo was evaluated using the β-γ coincidence technique. A liquid sample of Mo was prepared from aMo/Tc generator and measured in a 4παβ(LS)-γ(HPGe) system that comprises a Liquid Scintillator (LS) detector and a High-Purity Germanium (HPGe) detector. The sample was introduced into scintillation fluid embedded in a photo-reflector assembly that provides almost 100% efficiency for detecting β particles (in the energy range of intreset). The combination of the HPGe and the LS detectors provided a highly effective rejection mechanism for non-coincident events. Thereby, the distinction between the detected 140.5 keV events originating from decays of Tc (IT) and those from transitions bypassing the metastable state could be obtained and the 'prompt' intensity was evaluated directly. The system was calibrated for detecting β particles and γ-rays using radioactive sources of known activities and having identical geometry as the sample containing Mo. The absolute intensity of the 'prompt' 140.5 keV was found to be (5.21 ± 0.02±0.16)%, in good agreement with results from more recently reported works.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2022.110367DOI Listing

Publication Analysis

Top Keywords

intensity 'prompt'
12
'prompt' 1405 kev
12
absolute intensity
8
detecting particles
8
evaluating intensity
4
'prompt'
4
1405 kev
4
1405 kev γ-ray
4
γ-ray 4παβls-γhpge
4
4παβls-γhpge measurement
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!