The interface design of inorganic and organic halide perovskite-based devices plays an important role to attain high performance. The modification of transport layers (ETL and HTL) or the perovskite layer is given the crucial inspiration to realize superior power conversion efficiencies (PCEs). The highly conducting 2D materials of CNT, graphene/GO, and transition-metal dichalcogenides (TMDs) are suitable substitutes to tune the electronic structure/work function of perovskite devices. Herein, the nanocomposites composed of molybdenum dichalcogenides (MoX = MoS, MoSe, and MoTe) stretched CNT was embedded with HTL or perovskite layer to improve the resulted characteristics of perovskite devices of solar cells and X-ray detectors. A superior solar cell efficiency of 12.57% was realized for the MoTe@CNT nanocomposites using a modified active layer-composed device. Additionally, X-ray detectors with MoTe@CNT-modulated active layers achieved 13.32 μA/cm, 3.99 mA/Gy·cm, 4.81 × 10 cm/V·s, and 2.13 × 10 cm/V·s of CCD-DCD, sensitivity, mobility, and trap density, respectively. Density functional theory approximation was used to realize the improved electronics properties, optical properties, and energy band structures in the MoX@CNT-doped perovskites evidently. Thus, the current research paves the way for the improvement of highly efficient semiconductor devices based on perovskite-based structures with the use of 2D nanocomposites.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acsami.2c08842 | DOI Listing |
Eur Radiol Exp
January 2025
Unit of Medical Physics, Pisa University Hospital "Azienda Ospedaliero-Universitaria Pisana", Pisa, Italy.
Background: Photon-counting detector (PCD) technology has the potential to reduce noise in computed tomography (CT). This study aimed to carry out a voxelwise noise characterization for a clinical PCD-CT scanner with a model-based iterative reconstruction algorithm (QIR).
Methods: Forty repeated axial acquisitions (tube voltage 120 kV, tube load 200 mAs, slice thickness 0.
Insights Imaging
January 2025
Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, People's Republic of China.
Objectives: This study aimed to investigate the diagnostic value of spectral parameters of dual-layer spectral detector computed tomography (DLCT) in distinguishing between low- and high-grade bladder cancer (BCa).
Methods: This single-center retrospective study included pathologically confirmed BCa patients who underwent preoperative contrast-enhanced DLCT. Patients were divided into low- and high-grade groups based on pathology.
Radiographics
January 2025
From the Mallinckrodt Institute of Radiology, Washington University in St. Louis School of Medicine, 510 S Kingshighway Blvd, St. Louis, MO 63110.
Historically, evaluation of the upper extremity vasculature was performed using digital subtraction angiography. With the advancement of cross-sectional imaging and submillimeter isotropic data acquisition, CT angiography (CTA) has become an excellent noninvasive diagnostic tool for evaluation of the vasculature of the upper extremities. CTA allows quick evaluation of vessel patency and irregularity and achievement of the anatomic detail needed in preoperative planning.
View Article and Find Full Text PDFTuberk Toraks
December 2024
Department of Neurosurgery, Yale University Faculty of Medicine, New Haven, United States.
Introduction: This study aimed to evaluate the imaging findings of the chest flat panel detector computed tomography (FDCT) among coronavirus disease-2019 (COVID-19) positive patients during urgent/emergent interventional neuroradiologic procedures.
Materials And Methods: Chest FDCT examinations were performed using a C-arm mounted FDCT within the interventional radiology (IR) suite if the reverse transcription polymerase chain reaction (RT-PCR) results were pending in patients with clinical findings suggestive of COVID-19. In those who already had positive RT-PCR results, FDCT was performed for acute evaluation only if an acute unexpected cardiopulmonary event occurred during the procedure.
Chem Commun (Camb)
January 2025
Wuhan National Laboratory for Optoelectronics and School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China.
Quasi-2D DJ type perovskites theoretically offer excellent properties for X-ray detection, but they often face issues such as phase segregation and small crystal size. In this study, we synthesized large single crystals of quasi-2D DJ type perovskite (3AMPY)(MA)PbBr using temperature-controlled crystallization. The resulting X-ray detector exhibited high resistivity (1.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!