• Percutaneous closure of ASDs can be limited by size or shape of the defect. • A 3D evaluation of ASDs is essential for proper sizing and procedural planning. • Balloon sizing may help for large or irregularly shaped ASDs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9271411PMC
http://dx.doi.org/10.1016/j.case.2022.03.008DOI Listing

Publication Analysis

Top Keywords

percutaneous closure
8
defect •
8
limitations percutaneous
4
closure complex
4
complex secundum
4
secundum atrial
4
atrial septal
4
septal defect
4
• percutaneous
4
closure asds
4

Similar Publications

Antegrade femoral puncture Using a Suture-Mediated Closure Device in infrainguinal endovascular interventions.

Ann Vasc Surg

December 2024

Department of Vascular Surgery, IRCCS Sacro Cuore-Don Calabria, Negrar, VR, Italy.

Introduction: ProGlide is a suture-mediated vascular closure device (VCD) indicated for retrograde access closure at the common femoral artery (CFA). However, its off-label use for antegrade and/or superficial femoral artery (SFA) access has become common in many practices. This study evaluated the efficacy and safety of ProGlide for femoral artery access closure in patients undergoing antegrade infrainguinal endovascular procedures.

View Article and Find Full Text PDF

Background: Traditional decannulation of femoral veno-arterial extracorporeal membrane oxygenation (VA-ECMO) involves femoral cutdown. Percutaneous methods have been developed, but data supporting their use is limited. We sought to compare the MANTA vascular closure device to open decannulation.

View Article and Find Full Text PDF

A 73-year-old man who had undergone esophagectomy and retrosternal gastric tube reconstruction for esophageal cancer 8 years prior was transferred to our hospital for the treatment of an acute myocardial infarction. Emergent percutaneous coronary intervention for the left anterior descending artery (#7) was successfully performed. However, echocardiography revealed a ventricular septal rupture (25×27 mm).

View Article and Find Full Text PDF

Background: Patent ductus arteriosus (PDA) is a congenital heart defect that requires closure to prevent complications like heart failure and pulmonary hypertension. Catheter-based closure using devices such as the Amplatzer duct occluder is the preferred method due to its minimally invasive nature. However, device embolization is a rare but recognized complication, particularly in small children or high-flow PDAs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!