AI Article Synopsis

  • Lung cancers can recur if the surgical margins are not adequate, especially difficult to gauge in pulmonary ground glass opacities (GGOs).
  • A new technique called three-dimensional near-infrared specimen mapping (3D-NSM) was tested on 20 patients to improve margin assessment during GGO resections using a fluorescent tracer.
  • Results showed that 3D-NSM accurately identified all GGOs and their margins with close alignment to final pathology results, suggesting it can rapidly help surgeons determine if resection margins are sufficient.

Article Abstract

Background: Lung cancers can recur locally due to inadequate resection margins. Achieving adequate margin distances is challenging in pulmonary ground glass opacities (GGOs) because they are not easily palpable. To improve margin assessment during resection of GGOs, we propose a novel technique, three-dimensional near-infrared specimen mapping (3D-NSM).

Methods: Twenty patients with a cT1 GGO were enrolled and received a fluorescent tracer preoperatively. After resection, specimens underwent 3D-NSM in the operating room. Margins were graded as positive or negative based upon fluorescence at the staple line. Images were analyzed using ImageJ to quantify the distance from the tumor edge to the nearest staple line. This margin distance calculated by 3D-NSM was compared to the margin distance reported on final pathology several days postoperatively.

Results: 3D-NSM identified 20/20 GGOs with no false positive or false negative diagnoses. Mean fluorescence intensity for lesions was 110.92 arbitrary units (A.U.) (IQR: 77.77-122.03 A.U.) compared to 23.68 A.U. (IQR: 19.60-27.06 A.U.) for background lung parenchyma (p < 0.0001). There were 4 tumor-positive or close margins in the study cohort, and all 4 (100%) were identified by 3D-NSM. 3D-NSM margin distances were nearly identical to margin distances reported on final pathology (R = 0.9362). 3D-NSM slightly under-predicted margin distance, and the median difference in margins was 1.9 mm (IQR 0.5-4.3 mm).

Conclusions: 3D-NSM rapidly localizes GGOs by fluorescence and detects tumor-positive or close surgical margins. 3D-NSM can accurately quantify the resection margin distance as compared to formal pathology, which allows surgeons to rapidly determine whether sublobar resection margin distances are adequate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10237678PMC
http://dx.doi.org/10.1007/s11307-022-01750-0DOI Listing

Publication Analysis

Top Keywords

three-dimensional near-infrared
8
near-infrared specimen
8
specimen mapping
8
distance tumor
8
pulmonary ground
8
ground glass
8
glass opacities
8
background lung
8
margin distance
8
margin
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!