Objectives: To examine the relationship between endothelial dysfunction and adverse cardiovascular events in patients with paroxysmal atrial fibrillation (AF).
Methods: In this prospective observational study, flow-mediated dilation (FMD) was measured by ultrasound in 291 patients with paroxysmal AF. Then, the patients were divided into low FMD group (n=97, FMD of <5.9%) or high FMD group (n=194, FMD of ≥5.9%). Patients were followed up for at least 30 months. Primary end point was cardiovascular events (stroke, heart failure hospitalization, cardiovascular death, and non-fatal myocardial infarction) and second endpoint was heart failure hospitalization, or stroke.
Results: Rate of cardiovascular events was higher in low FMD group compared with high FMD group (37.1% versus 18%, <0.001). This higher risk of cardiovascular events in patients with low FMD was primarily due to a higher risk of heart failure hospitalization compared with patients with high FMD (19.6% versus 10.8%, <0.05). There was no significant difference of stroke between both groups. Cox proportional hazards ratio (HR) analysis showed that low FMD (HR: 3.036, 95% CI: [1.546-5.963], CHA2DS2-VASc scores (HR: 1.383, 95% CI: [1.035-1.847]), and left atrial diameter (HR: 1.304, 95% CI: [1.001-1.069]) were independent predictors for composite cardiovascular events.
Conclusion: In patients with paroxysmal AF, endothelial dysfunction was associated with composite cardiovascular events. Flow-mediated dilation was a significant predictor of cardiovascular events in patients with paroxysmal AF.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9749696 | PMC |
http://dx.doi.org/10.15537/smj.2022.43.7.20220214 | DOI Listing |
Clin Radiol
December 2024
Department of Neurology, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China. Electronic address:
Aim: To provide a theoretical basis for the study of the pathogenesis of residual dizziness (RD) from the perspective of imaging.
Materials And Methods: The general clinical data of the RD group and healthy control (HC) group were statistically analysed by two independent sample t tests, rank sum tests or chi-square tests. The imaging data of the two groups of people were preprocessed and statistically analysed by using the data processing and analysis for brain imaging (DPABI) software package.
J Cardiovasc Electrophysiol
January 2025
Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China.
Background: Pulsed field ablation (PFA) is gaining recognition as a nonthermal, tissue-specific technique for the treatment of atrial fibrillation (AF). The preclinical evaluation of the investigated novel PFA system from Insight Medtech Co. Ltd has demonstrated feasibility, safety, and 30-day efficacy for pulmonary vein isolation (PVI) in the swine model.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
January 2025
Department of Electrophysiology, German Heart Center Munich, TUM University Hospital, Munich, Bavaria, Germany.
Introduction: Data regarding safety and long-term outcome of very high-power-short duration (vHPSD) ablation in adult congenital heart disease (ACHD) patients with paroxysmal or persistent atrial fibrillation (AF) are lacking.
Methods: Retrospective observational single-center study. The data of 66 consecutive ACHD patients (mean age 60 ± 12.
Acad Emerg Med
January 2025
Emergency Department, Paris Saint-Joseph Hospital Group, Paris, France.
Background: Vertigo is a priority for training and decision support in emergency departments (ED). Benign paroxysmal positional vertigo (BPPV), though manageable at bedside, remains frequently underdiagnosed and undertreated. This study assessed the effectiveness of a two-tiered educational intervention on posterior and horizontal BPPV management in the ED setting.
View Article and Find Full Text PDFJ Neurol
January 2025
Department of Neurology, University of Chicago, 5841 South Maryland Avenue, Chicago, IL, 60637, USA.
Positional downbeat nystagmus (pDBN) is a common finding in dizzy patients, with etiologies ranging from benign paroxysmal positional vertigo (BPPV) to central vestibular lesions. Although peripheral pDBN often presents with distinct clinical features that differentiate it from BPPV, diagnosing its etiology can be challenging. A thorough clinical evaluation, including the physical characteristics of the nystagmus, response to positional maneuvers, and neurological findings, is often sufficient to diagnose conditions that provoke pDBN such as anterior canal BPPV, atypical posterior canal BPPV, and central causes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!