Clinical comparison of diode laser- and LED-activated tooth bleaching: 9-month follow-up.

Lasers Med Sci

Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Sıhhıye, 06100, Ankara, Turkey.

Published: October 2022

This study aims to evaluate the effect of diode laser- or LED-activated tooth bleaching on color change, tooth sensitivity(TS), temperature variation, and gingival irritation (GI) for 9 months. Thirty-five subjects having anterior teeth with a color of A2 or darker were enrolled in the study. In a split-mouth design, one side of each arch was activated by a diode laser (Epic X, Biolase), and the other side was activated by an LED (Radii Plus, SDI) in conjunction with a bleaching agent (35%, Whiteness HP). The color change was evaluated by subjective (VitaClassic/Vita3D Master Bleachguide) and objective (spectrophotometer, Vita Easyshade) methods for up to 9 months. TS and GI were assessed by visual analogue scale (VAS) and gingival index, respectively, at the same recall periods. During the bleaching, the temperature variation was also recorded using a thermocouple. Statistical analyses were performed (p < 0.05). In the color evaluation, no statistically significant difference was found between diode laser and LED (p > 0.05), except for the 6-month spectrophotometric assessment (ΔE, ΔE), where higher values were obtained with the laser (p < 0.05). The temperature difference and maximum temperature with diode were found to be significantly higher than LED (p < 0.05). Higher values were obtained with LED when the mean temperatures were compared (p < 0.05). There was no difference between the two activation methods in terms of TS and GI at any of the recalls (p > 0.05). The bleaching activated either with diode laser or LED performed similar clinical performance in terms of effective color change, tooth sensitivity, and gingival irritation with minimum temperature variations.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10103-022-03612-1DOI Listing

Publication Analysis

Top Keywords

diode laser-
8
laser- led-activated
8
led-activated tooth
8
tooth bleaching
8
color change
8
temperature variation
8
clinical comparison
4
comparison diode
4
bleaching
4
bleaching 9-month
4

Similar Publications

This study presents a novel optoporation technique using a titanium-coated TiO microstructure (TMS) device activated by an infrared diode laser for highly efficient intracellular delivery. The TMS device, fabricated with 120 nm titanium coating on a titanium dioxide (TiO) microstructure containing microneedles (height ∼2 μm and width ∼4.5 μm), demonstrates enhanced biocompatibility and thermal conductivity compared to the conventional TiO microstructure (MS).

View Article and Find Full Text PDF

The aim of this study was to compare the effectiveness of different types of low level laser treatment (LLLT) in reducing pain levels, changing oxygen saturation and bite force in patients with myofacial pain syndrome (MPS). 45 patients were randomly assigned to three groups: Group 1 (GRR laser, n = 15) received LLLT with Gallium-Aluminium-Arsenide (GaAlAs) diode laser with a wavelength of 904 nm and red laser with a wavelength of 650 nm over masseter muscle region. Group 2 (Nd: YAG laser, n = 15) were treated with Neodymium-doped Yttrium Aluminium Garnet laser with a wavelength of 1064 nm and the same protocol with Nd: YAG laser was performed in the Group 3 (placebo, n = 15) using sham device.

View Article and Find Full Text PDF

This in-vitro study assessed the influence of the shade of human teeth on the transmission of near-infrared light. A total of 40 teeth were used. After cleaning the root surface and removing cementum, the teeth were sectioned into slices 3 mm thick, with each comprising a portion of the crown (enamel-dentine (ED)) and of the root (dentine only).

View Article and Find Full Text PDF

Oral candidiasis, predominantly caused by , presents significant challenges in treatment due to increasing antifungal resistance and biofilm formation. Antimicrobial photodynamic therapy (aPDT) using natural photosensitizers like riboflavin and hypericin offers a potential alternative to conventional antifungal therapies. : A systematic review was conducted to evaluate the efficacy of riboflavin- and hypericin-mediated aPDT in reducing Candida infections.

View Article and Find Full Text PDF

Mid-infrared spectral analysis has long been recognized as the most accurate noninvasive blood glucose measurement method, yet no practical compact mid-infrared blood glucose sensor has ever passed the accuracy benchmark set by the USA Food and Drug Administration (FDA): to substitute for the finger-pricking glucometers in the market, a new sensor must first show that 95% of their glucose measurements have errors below 15% of these glucometers. Although recent innovative exploitations of the well-established Fourier-transform infrared (FTIR) spectroscopy have reached such FDA accuracy benchmarks, an FTIR spectrometer is too bulky. The advancements of quantum cascade lasers (QCLs) can lead to FTIR spectrometers of reduced size, but compact QCL-based noninvasive blood glucose sensors are not yet available.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!