Objective The aim of this experimental study was to test the possibility of applying internal sinus elevation techniques using controlled hydrodynamic or pneumatic pressure and evaluate their elevation effectiveness. Materials and methods A device was specially designed for this study and was used to elevate the sinus membrane internally in 12 halves of freshly slaughtered sheep heads. The sample was divided into two groups randomly according to the type of controlled pressure applied (hydrodynamic or pneumatic). The elevation height of the membrane was measured in addition to investigating the presence or absence of perforation. Results The maxillary sinus membranes started to be elevated at an average pressure value of 21.6 ± 7.5 millibars (mbar) when hydrodynamic pressure was applied, and at an average pressure value of 23.3 ± 8.1 mbar when pneumatic pressure was applied. The mean values ​​of elevation height after applying the controlled hydrodynamic and pneumatic pressure were 13.00 ± 2.76 and 10.33 ± 3.88 mm, respectively. No perforations occurred in either of the groups. Conclusions The use of a controlled hydrodynamic or pneumatic pressure, which is appropriate for the characteristics of the maxillary sinus membrane in the process of internal elevation, is effective, and it yielded an amount of lifting similar to that we get when using the external elevation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9271324PMC
http://dx.doi.org/10.7759/cureus.26711DOI Listing

Publication Analysis

Top Keywords

hydrodynamic pneumatic
20
pneumatic pressure
20
controlled hydrodynamic
16
maxillary sinus
12
pressure applied
12
pressure
9
sinus elevation
8
sinus membrane
8
elevation height
8
average pressure
8

Similar Publications

Empirical Data-Driven Linear Model of a Swimming Robot Using the Complex Delay-Embedding DMD Technique.

Biomimetics (Basel)

January 2025

Group of Biomechatronics, Fachgebiet Biomechatronik, Technische Universität Ilmenau, D-98693 Ilmenau, Germany.

Anguilliform locomotion, an efficient aquatic locomotion mode where the whole body is engaged in fluid-body interaction, contains sophisticated physics. We hypothesized that data-driven modeling techniques may extract models or patterns of the swimmers' dynamics without implicitly measuring the hydrodynamic variables. This work proposes empirical kinematic control and data-driven modeling of a soft swimming robot.

View Article and Find Full Text PDF

Sheath-enhanced concentration and on-chip detection of bacteria from an extremely low-concentration level.

Lab Chip

December 2024

Department of Chemical and Environmental Engineering, University of California, Riverside, Riverside, CA 92507, USA.

Microfluidic-based sheath flow focusing methods have been widely used for efficiently isolating, concentrating, and detecting pathogenic bacteria for various biomedical applications due to their enhanced sensitivity and exceptional integration. However, such a microfluidic device usually needs complicated device fabrication and sample dilution, hampering the efficient and sensitive identification of target bacteria. In this study, we develop and fabricate a sheath-assisted and pneumatic-induced nano-sieve device for achieving the improved on-chip concentration and sensitive detection of (MRSA).

View Article and Find Full Text PDF

Simulation study on hydrogen concentration distribution in hydrogen blended natural gas transportation pipeline.

PLoS One

December 2024

Pneumatic and Thermodynamic Energy Storage and Supply Beijing Key Laboratory, Beijing, China.

Hydrogen is a clean energy source, and blending it with natural gas in existing pipeline networks is a key transition solution for transportation cost reduction. However, during the transportation process, a non-uniform distribution of hydrogen concentration occurs in the pipeline due to gravity. Therefore, it is necessary to study the hydrogen concentration distribution law of hydrogen-blended natural gas in pipelines.

View Article and Find Full Text PDF

A quadruped robot with intelligent properties is developed using a bionics approach to explore the potential value of gecko-like machinery. The robot structure incorporates mechanical links, steering engines, and wheel groups, which can expand the movement function of its leg joint. A pneumatic control circuit that can generate negative pressure is built by a vacuum pump, electromagnetic valve, sucker, hose, and others, to enable mobile climbing and adsorption of the gecko-inspired robot.

View Article and Find Full Text PDF

Three-dimensional (3D) bioprinting is the use of computer-controlled transfer processes for assembling bioinks (cell clusters or materials loaded with cells) into structures of prescribed 3D organization. The correct bioprinting parameters ensure a fast and accurate bioink deposition without exposing the cells to harsh conditions. This study seeks to optimize pneumatic extrusion-based bioprinting based on hydrogel flow rate and extrusion speed measurements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!