Timely detection of portal hypertension as a manifestation in a subgroup of patients with common variable immunodeficiency (CVID) represents a challenge since it is usually not associated with liver cirrhosis. To identify relevant markers for portal hypertension, we evaluated clinical history, laboratory parameters, and abdominal ultrasound including liver elastography and biomarkers of extracellular matrix formation. Twenty seven (6%) of 479 CVID patients presented with clinically significant portal hypertension as defined by either the presence of esophageal varices or ascites. This manifestation occurred late during the course of the disease (11.8 years after first diagnosis of CVID) and was typically part of a multiorgan disease and associated with a high mortality (11/27 patients died during follow up). The strongest association with portal hypertension was found for splenomegaly with a longitudinal diameter of > 16 cm. Similarly, most patients presented with a liver stiffness measurement (LSM) of above 6.5 kPa, and a LSM above 20 kPa was always indicative of manifest portal hypertension. Additionally, many laboratory parameters including Pro-C4 were significantly altered in patients with portal hypertension without clearly increasing the discriminatory power to detect non-cirrhotic portal hypertension in CVID. Our data suggest that a spleen size above 16 cm and an elevated liver stiffness above 6.5 kPa should prompt further evaluation of portal hypertension and its sequelae, but earlier and better liquid biomarkers of this serious secondary complication in CVID are needed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9700587PMC
http://dx.doi.org/10.1007/s10875-022-01319-0DOI Listing

Publication Analysis

Top Keywords

portal hypertension
36
portal
9
hypertension
9
detection portal
8
patients common
8
common variable
8
variable immunodeficiency
8
laboratory parameters
8
patients presented
8
liver stiffness
8

Similar Publications

Unlabelled: Sinusoidal obstruction syndrome (SOS) is a distinctive and potentially fatal form of hepatic injury that mainly occurs after hematopoietic-stem cell transplantation but also due to many other conditions including drug or toxin exposure. Recently, immune checkpoint inhibitors (ICIs) have revolutionised the treatment of many solid organ malignancies. Furthermore, as their use has become more widespread, rare toxicities have emerged.

View Article and Find Full Text PDF

Portal vein recanalization transjugular intrahepatic portosystemic shunt (PVR-TIPS) is a safe and effective procedure for decompression of portal hypertension (PH). In this short case series, 2 women with chronic noncirrhotic portal vein thrombosis were treated with PVR-TIPS. Both patients hoped to conceive.

View Article and Find Full Text PDF

Purpose: This study assesses the efficacy and safety of Portal Vein Recanalization with Intrahepatic Portosystemic Shunt (PVR-TIPS) in non-cirrhotic patients with chronic portal vein occlusion (CPVO), cavernomatous transformation, and symptomatic portal hypertension (PH) and/or portal vein thrombotic progression.

Material And Methods: Medical records of 21 non-cirrhotic patients with CPVO and portal cavernoma undergoing PVR-TIPS were analyzed. Hemodynamic (intraprocedural reduction in portosystemic pressure gradient), clinical (data on gastrointestinal bleeding, abdominal pain, ascites, and presence of esophageal varices from imaging exams) and technical success (PVR-TIPS) assessed efficacy.

View Article and Find Full Text PDF

Numerical assessment of portal pressure gradient (PPG) based on clinically measured hepatic venous pressure gradient (HVPG) for liver cirrhosis patients.

J Biomech

January 2025

Department of Gastroenterology and Hepatology and West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, PR China; Med-X Center for Informatics, Sichuan University, Chengdu, Sichuan 610041, PR China. Electronic address:

Portal hypertension (PH) is the initial and main consequence of liver cirrhosis. Hepatic venous pressure gradient (HVPG) measurement has been widely used to estimate portal pressure gradient (PPG) and detect portal hypertension. However, some clinical studies have found poor correlation between HVPG and PPG, which may lead to the misdiagnosis of portal hypertension.

View Article and Find Full Text PDF

The use of ultrasound contrast agents (UCAs) for estimating portal pressure has recently gained attention due to its clinical promise, yet variability in acoustic amplitude poses challenges. UCAs contain microbubbles (1-10 µm in diameter), and understanding their acoustic response is essential to address this variability. However, systematic exploration of factors influencing microbubble behavior remains limited in current literature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!