A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Surgical Navigation System for Hypertensive Intracerebral Hemorrhage Based on Mixed Reality. | LitMetric

Hypertensive intracerebral hemorrhage (HICH) is an intracerebral bleeding disease that affects 2.5 per 10,000 people worldwide each year. An effective way to cure this disease is puncture through the dura with a brain puncture drill and tube; the accuracy of the insertion determines the quality of the surgery. In recent decades, surgical navigation systems have been widely used to improve the accuracy of surgery and minimize risks. Augmented reality- and mixed reality-based surgical navigation is a promising new technology for surgical navigation in the clinic, aiming to improve the safety and accuracy of the operation. In this study, we present a novel multimodel mixed reality navigation system for HICH surgery in which medical images and virtual anatomical structures can be aligned intraoperatively with the actual structures of the patient in a head-mounted device and adjusted when the patient moves in real time while under local anesthesia; this approach can help the surgeon intuitively perform intraoperative navigation. A novel registration method is used to register the holographic space and serves as an intraoperative optical tracker, and a method for calibrating the HICH surgical tools is used to track the tools in real time. The results of phantom experiments revealed a mean registration error of 1.03 mm and an average time consumption of 12.9 min. In clinical usage, the registration error was 1.94 mm, and the time consumption was 14.2 min, showing that this system is sufficiently accurate and effective for clinical application.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9712880PMC
http://dx.doi.org/10.1007/s10278-022-00676-xDOI Listing

Publication Analysis

Top Keywords

surgical navigation
16
navigation system
8
hypertensive intracerebral
8
intracerebral hemorrhage
8
mixed reality
8
real time
8
registration error
8
time consumption
8
surgical
5
navigation
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!