A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Arthroscopic rod technique compared to stress ultrasound in the dynamic evaluation of lateral ligament instabilities of the elbow. | LitMetric

Introduction: The purpose was to compare the arthroscopic rod technique to stress ultrasound in the dynamic assessment of lateral elbow instabilities.

Materials And Methods: Fifteen elbows of eight specimen with a mean age of 66.4 ± 13.3 years were assessed in a prone position following a defined dissection setup. After evaluation of the native status, an arthroscopic dissection of the radial collateral ligament (RCL) or lateral ulnar collateral ligament (LUCL), and finally of entire capsuloligamentous structures was performed. Three raters examined each state (native, RCL or LUCL lesion, complete lesion) with the arthroscopic rod technique in 90° flexion and with stress ultrasound in 30 and 90° flexion. The intra-class correlation coefficient (ICC) was calculated to assess the interrater reliability as well as test-retest reliability for each testing modality (arthroscopy and ultrasound).

Results: The arthroscopic rod technique showed a superior interrater and test-retest reliability of 0.953 and 0.959 (P < 0.001), respectively, when compared to stress ultrasound with an ICC of 0.4 and 0.611 (P < 0.001). A joint space opening during arthroscopy of > 6 mm humero-ulnar or > 7 mm humero-radial was indicative for a lateral collateral ligament lesion. However, a differentiation between an isolated RCL or LUCL tear was not possible. A lateral joint opening of ≥ 9 mm was only observed in complete tears of the lateral capsuloligamentous complex.

Conclusions: The arthroscopic rod technique showed a superior interrater and test-retest reliability when compared to stress ultrasound. Arthroscopic assessment for radial elbow instability was found to be reliable and reproducible. A joint gapping ≥ 9 mm in the arthroscopic evaluation is a sign for a complete insufficiency of the radial capsuloligamentous complex. However, it is not possible to precisely distinguish between a lesion of the RCL or LUCL by arthroscopy. On the basis of our results, dynamic ultrasound testing may be inappropriate to objectify lateral elbow instability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10030401PMC
http://dx.doi.org/10.1007/s00402-022-04491-5DOI Listing

Publication Analysis

Top Keywords

arthroscopic rod
20
rod technique
20
stress ultrasound
16
collateral ligament
12
rcl lucl
12
test-retest reliability
12
arthroscopic
8
compared stress
8
ultrasound dynamic
8
lateral elbow
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!