Background: Although most paediatric radial neck fractures can be treated with closed reduction, some severely displaced fractures require open reduction. The purpose of this study is to compare the effects of ESIN and KW fixation in open reduction of radial neck fracture in children.
Methods: Twenty-four patients with mean age of 8.5 years were included. Four of the patients had a Judet type III fracture and 20 had a Judet type IV fracture. Ten patients who underwent percutaneous KW fixation were assigned to group A, while 14 patients who underwent ESIN fixation were assigned to group B. Variables of interest included age, sex, fracture type, associated lesions, surgical time, fracture reduction, cost, follow-up, healing time, X-rays, clinical outcomes, and complications.
Results: There were no significant between-group differences in sex, age, additional injuries, fracture type, and quality of reduction. Costs were significantly lower in Group A. Fracture healing was achieved in 23 of 24 patients (10/10 in group A and 13/14 in group B). In a postoperative elbow function assessment based on the Steele and Graham classification, 80% of patients in group A had a score of excellent or good, compared to 78.6% of patients in group B. Two cases of nail shifting and joint protrusion were observed in group B, one of which also presented with nonunion during follow-up.
Conclusions: Both KW and ESIN may achieve good clinical outcomes, but KW is associated with lower costs, easier implant removal (without the need for a secondary surgery), and lower iatrogenic complications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9232670 | PMC |
http://dx.doi.org/10.1007/s43465-022-00631-6 | DOI Listing |
J Glaucoma
January 2025
Wills Eye Hospital Glaucoma Service, Philadelphia, PA, USA.
Prcis: In the real-world, retrospective, EXPAND study of consecutive adults with glaucoma, ab-externo gel stent implantation effectively lowered intraocular pressure (34%) and the medication burden (61%), with transient/self-resolving hypotony as the most frequent adverse event (28%).
Purpose: To assess effectiveness and safety of ab-externo gel stent (GS) implantation in glaucoma.
Methods: Multicenter, real-world, retrospective study.
Chem Biodivers
January 2025
Department of Pharmaceutical Sciences, College of Health Sciences and Pharmacy, Chicago State University, Chicago, Illinois, USA.
This study was undertaken to assess the antioxidant and neuropharmacological potentials of the methanol leaf extract of Acanthus ebracteatus (MAEL) through experimental and in silico methods. The phytochemical screening (PS) and GC-MS (gas chromatography-mass spectrometry) identified 28 phytochemicals with different classes in nature in MAEL. The MAEL revealed better antioxidant activity through various in vitro antioxidant assays.
View Article and Find Full Text PDFJ Dent Sci
January 2025
Department of Oral and Maxillofacial Surgery, Kobe City Medical Center General Hospital, Kobe, Japan.
J Orthop
August 2025
University of Turin, Centro Traumatologico Ortopedico (CTO), Department of Orthopaedic Surgery, Turin, Italy.
Introduction: Sacroiliac joint (SIJ) dislocations, particularly pure SIJ dislocations without associated fractures, represent a rare and complex subset of pelvic ring injuries. Given the intricate pelvic anatomy and the need to achieve both stability and functional recovery, the optimal surgical management for these injuries remains a topic of debate. This systematic review aims to evaluate the various surgical techniques employed in treating this rare and challenging injury and assess associated clinical outcomes and complications.
View Article and Find Full Text PDFCureus
January 2025
Research and Development, Encoll Corporation, Fremont, USA.
The increased cost and morbidity associated with diabetic foot ulcers (DFUs) place a substantial strain on the entire global healthcare system. In this trial, 24 subjects with a chronic DFU, Wagner grade 1 (University of Texas grade 1A), were treated with Standard of Care (SOC) therapy and randomized, one-half to receive advanced high-purity Type-I collagen-based skin substitute (HPTC; manufactured by Encoll Corp., Fremont, CA, USA), and the other half to receive a dehydrated human amnion/chorion membrane (dHACM) or viable cryopreserved human placental membrane (vCHPM).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!