Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This work aims to evaluate the application of optical and X-ray spectroscopy methods to determine the effect of alpha-emitting radionuclides on the properties of solid-state nuclear track detectors (SSNTD) based on nitrocellulose during their detection. The proposed estimation methods are alternative methods to standard technologies, making it possible to determine the concentration of radon and its decay products without the chemical etching of film detectors and subsequent direct counting of the formed latent tracks from interacting particles. During the research, it was found that the use of optical spectroscopy and X-ray diffraction methods makes it possible to qualitatively determine the irradiation effect on changes in the properties of film detectors when α-particles with different energies pass through them. At the same time, a comparison of the data of optical spectroscopy, X-ray diffraction and the visualization of latent tracks after chemical etching made it possible to establish that a part of the registered α-particles in living quarters has an energy of less than 2.5 MeV, which is not enough to pass through the polymer film of the detector, as a result of which well-like tracks are formed. An increase in the intensity of the interference bands in the region above 700 nm and a decrease in the intensity of diffraction reflection characterized the changes in optical transmission. The penetration of the α-particles through the detecting film decreases the film's transmission capacity, forming an anisotropic change in diffraction reflections associated with a change in the film's structure and defective fractions distorting the molecular structure.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9269325 | PMC |
http://dx.doi.org/10.3390/polym14132731 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!