: The aim of this study was to analyze the relevance of asymmetry features between both eyes of the same patient for glaucoma screening using optical coherence tomography. : Spectral-domain optical coherence tomography was used to estimate the thickness of the peripapillary retinal nerve fiber layer in both eyes of the patients in the study. These measurements were collected in a dataset from healthy and glaucoma patients. Several metrics for asymmetry in the retinal nerve fiber layer thickness between the two eyes were then proposed. These metrics were evaluated using the dataset by performing a statistical analysis to assess their significance as relevant features in the diagnosis of glaucoma. Finally, the usefulness of these asymmetry features was demonstrated by designing supervised machine learning models that can be used for the early diagnosis of glaucoma. : Machine learning models were designed and optimized, specifically decision trees, based on the values of proposed asymmetry metrics. The use of these models on the dataset provided good classification of the patients (accuracy 88%, sensitivity 70%, specificity 93% and precision 75%). : The obtained machine learning models based on retinal nerve fiber layer asymmetry are simple but effective methods which offer a good trade-off in classification of patients and simplicity. The fast binary classification relies on a few asymmetry values of the retinal nerve fiber layer thickness, allowing their use in the daily clinical practice for glaucoma screening.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9269200 | PMC |
http://dx.doi.org/10.3390/s22134842 | DOI Listing |
BMC Ophthalmol
January 2025
Department of Ophthalmology, Medical Faculty, University Hospital of Cologne, Kerpener Strasse 62, 50937, Cologne, Germany.
Background/ Aims: To analyze the longitudinal change in Bruch's membrane opening minimal rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (pRNFL) thickness using optical coherence tomography (OCT) after implantation of a PRESERFLO® microshunt for surgical glaucoma management in adult glaucoma patients.
Methods: Retrospective data analysis of 59 eyes of 59 participants undergoing implantation of a PRESERFLO microshunt between 2019 and 2022 at a tertiary center for glaucoma management. Surgical management included primary temporary occlusion of the glaucoma shunt to prevent early hypotony.
Surv Ophthalmol
January 2025
Ophthalmic Research Center, Research Institute for Ophthalmology and Vision Science, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
The impact of various neurodegenerative diseases on the retina has been investigated in recent years using optical coherence tomography (OCT). Epilepsy, classified as a neurodegenerative disorder, has been indicated to affect the structural integrity of the retina. Moreover, there is ongoing debate regarding the relative contribution of disease pathogenesis and the consumption of anti-epileptic drugs (AEDs) to these retinal changes.
View Article and Find Full Text PDFClin Ophthalmol
January 2025
Retina Service, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA.
Purpose Of Review: Intimate partner violence (IPV) is a leading cause of death and disability across the world. We sought to investigate the prevalence and clinical presentation of ocular injuries in IPV.
Recent Findings: Literature review revealed 16 published studies that evaluated ocular injuries in IPV, of which the study types included 9 retrospective studies, 2 prospective, 1 review, 1 invited commentary, 2 case reports, and 1 population-based cross-sectional survey.
Ophthalmic Physiol Opt
January 2025
Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan.
Purpose: To investigate the repeatability of optical coherence tomography angiography (OCTA) parameters in participants with different severities of glaucoma.
Methods: Subjects with open-angle glaucoma were enrolled prospectively and categorised into mild (mean deviation [MD] of 24-2 visual field test ≥ -6 dB), moderate to advanced (-6 > MD ≥ -20 dB) and severe glaucoma groups (MD < -20 dB). OCTA was performed three times within a single visit to obtain superficial and deep macular vessel density (VD) and peripapillary vessel and capillary density.
Ultrasound J
January 2025
Faculdade de Medicina da Universidade de Lisboa, Lisbon, Portugal.
Background: There are significant discrepancies in the optic nerve sheath diameter (ONSD) reported in the literature. We aimed to determine the ultrasonographic imaging features of ONSD and ophthalmic vessels in a healthy population, using a standardized protocol, and to estimate the effect of demographics and positioning changes on imaging measurements.
Methods: We measured the mean values of the ONSD in supine and sitting position and the Doppler imaging parameters of the ophthalmic, central retinal and short posterior ciliary arteries.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!