Surgical explantation of failed transcatheter heart valves: indications and results.

Heart Vessels

Department of Cardiovascular Surgery, German Heart Center Munich, Technical University Munich, Lazarettstr. 36, 80636, Munich, Germany.

Published: December 2022

Given the recent surge in transcatheter heart valve replacement (THVR), cardiac surgeons will surely face the challenge of eventual explantation. The aim of this study was to determine indications for reoperation, while exploring pertinent technical aspects and survival after THV explantation in a cohort originally deemed high risk or even inoperable. Between February 2008 and March 2019, 31 patients with failed transcatheter aortic valve replacement (TAVR) underwent surgical explantations at our facility. Data were prospectively collected for retrospective analysis of procedural indications, technical issues, and postoperative survival. The major reason for TAVR removal was bioprosthetic valve failure (BVF) due to infective endocarditis (IE: 16/31 [51.6%]), non-structural (NSVD: 14/31 [45.2%]) and structural (SVD: 1/31 [3.2%]) valve deterioration accounting for the rest. Mean age at THV explantation was 76.3 ± 8.3 years, and median time from TAVR to explantation was 153 days (0 days-56.6 months). Median ICU and hospital stay were 6 days (1-44 days) and 23 days (8-62 days), respectively. Thirty-day and 1-year survival rates were 74.2% and 67.2%, respectively. Median follow-up interval after explantation was 364 days (3 days-80 months). Mean cardiopulmonary bypass time was 124.6 ± 46.8 min, and mean aortic cross-clamp time was 84.3 ± 32.9 min. There was no need for unplanned aortic root repair owing to tissue damage during dissection of the TAVR from surrounding tissue. The most common reason for THV explantation was (a) BVF for IE and (b) BVF secondary to NSVD. Although 30-day and 1-year mortality rates in this multimorbid cohort were predictably high, no procedural mortalities occurred.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9579090PMC
http://dx.doi.org/10.1007/s00380-022-02119-7DOI Listing

Publication Analysis

Top Keywords

thv explantation
12
failed transcatheter
8
transcatheter heart
8
valve replacement
8
explantation
6
surgical explantation
4
explantation failed
4
heart valves
4
valves indications
4
indications surge
4

Similar Publications

Background: A dilated native right ventricular outflow tract (RVOT) presents unique challenges for transcatheter management using balloon-expandable valves. The Alterra Adaptive Prestent was designed to expand transcatheter therapy to treat patients with dilated RVOTs.

Objectives: The aim of this study was to report 2-year outcomes of the main cohort of the ALTERRA (Multicenter Study of Congenital Pulmonic Valve Dysfunction Studying the SAPIEN 3 THV With the Alterra Adaptive Prestent) pivotal trial using the prestent with transcatheter pulmonary valve replacement.

View Article and Find Full Text PDF

Hydrodynamic Assessment of Explanted Degenerated Transcatheter Aortic Valves: Novel Insights Into Noncalcific and Calcific Mechanisms.

JACC Cardiovasc Interv

June 2024

Cardiovascular Translational Lab, Centre for Cardiovascular Innovation, Centre for Heart Lung Innovation, University of British Columbia, Vancouver, British Columbia, Canada. Electronic address:

Background: The etiology of transcatheter aortic valve (TAV) degeneration is poorly understood, particularly noncalcific mechanisms.

Objectives: The authors sought to investigate noncalcific and calcific mechanisms of TAV degeneration and evaluate their impact on leaflet function by bench testing, imaging, and histology.

Methods: TAV explants were obtained from the EXPLANT THV registry and clinical institutions.

View Article and Find Full Text PDF

Background And Aims: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE.

Methods: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the differences in outcomes between two types of failed transcatheter heart valves (balloon-expandable valves vs. self-expanding valves) during surgical explantation.
  • Analyzing data from 401 patients, it reveals that failed balloon-expandable valves had higher rates of certain complications like endocarditis and paravalvular leaks compared to self-expanding valves.
  • Overall, mortality rates and stroke rates were similar across both groups post-explantation, but concomitant mitral surgery emerged as a significant independent predictor of 1-year mortality for both valve types.
View Article and Find Full Text PDF

Development and testing of a transcatheter heart valve with reduced calcification potential.

Front Cardiovasc Med

December 2023

Department of Cardiothoracic Surgery, Robert W.M. Frater Cardiovascular Research Centre, University of the Free State, Bloemfontein, South Africa.

Introduction: Patients from developing countries who require heart valve surgery are younger and have less access to open heart surgery than those from developed countries. Transcatheter heart valves (THVs) may be an alternative but are currently unsuitable for young patients because of their inadequate durability. We developed and tested a THV utilizing two new types of decellularized bovine pericardial leaflets in an ovine model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!